2-
3
. Operation Characteristic Curve
<Cooling>
<Heating>
2-
4
. Capacity Variation ratio According to Temperature.
<Cooling>
<Heating>
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 100 110
Cu
rr
e
n
t
(A)
Compressor Speed (RPS)
0
2
4
6
8
10
12
0 10 20 30 40 50 60 70 80 90 100 110
Cu
rr
e
n
t
(A)
Compressor Speed (RPS)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage : 230V/ 50Hz
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage : 230V / 50Hz
RAS-B24J2KVSG-E
RAS-18J2KVSG-E
RAS-B22J2KVSG-E
RAS-B24J2KVSG-E
RAS-18J2KVSG-E
RAS-B22J2KVSG-E
Hea
ting
Capa
ci
ty
ra
tio
(%
)
120
100
80
60
40
20
0
-15
-10
-5
0
Outside Temperature ( ºC)
5
10
Capacity ratio : 100 %=
6.00
kW(RAS-
18
J2KVSG-E
)
7.00
kW(RAS-B
22
J2KVSG-E
)
8.00
kW(RAS-B
24
J2KVSG-E
)
Conditions
Indoor : DB 2
0
o
C/WB 1
5
o
C
Outdoor : DB
7
o
C/WB
6
o
C
Indoor Air Flow : High
Pipe Length :
7.
5m
Voltage : 230V / 50Hz
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
C
oo
lin
g
C
ap
ac
ity
ra
tio
(%
)
Outside Temperature (
o
C)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V / 50Hz
Capacity ratio : 100 %=
5.00kW(RAS-18J2KVSG-E
)
6.10kW(RAS-B22J2KVSG-E
)
7.00kW(RAS-B24J2KVSG-E
)
RAS-18J2KVSG-E
RAS-B22J2KVSG-E
RAS-B24J2KVSG-E
- 8 -