TEMPORARY OPERATION
12
In case of the misplaced or discharged remote control
Pressing the RESET button, the unit can start or stop
•
without using the remote control.
Operation mode is set on AUTOMATIC operation, preset
•
temperature is 25°C and fan operation is automatic
speed.
TIMER OPERATION
13
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
Setting the ON Timer
Setting the OFF Timer
1
Press
for enter ON timer setting Press
for enter OFF timer setting
2
Press
for select desired ON
timer.
Press
for select desired OFF
timer.
3
Press
for set timer.
Press
for set timer.
4
Press
for cancel timer.
Press
for cancel timer.
1
Press
for enter ON timer setting
4
Press
for select desired OFF
timer.
2
Press
for select desired
ON timer.
5
Press
3
Press
for enter OFF timer setting
6
Press
again during the
( or ) blink.
During the daily timer is activating, both arrows (
•
, ) are indicated.
Note:
Keep the remote control in accessible transmission to the indoor unit;
•
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
•
PRESET OPERATION
14
Set your preferred operation for future use. The setting will be memorized by the
unit for future operation (except air
fl
ow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The
P
mark displays.
3. Press
: Operate the preset operation.
AUTO RESTART OPERATION
15
To automatically restart the conditioner after the power failure (Power of the unit must
be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the
operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the
operation. (3 beep sound but OPERATION lamp does not blink)
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does
•
not activate.
This function is used when its circuit breaker is shared with other electrical
appliances. It limits the maximum current/ power consumption to 100%, 75% or
50%. The lower the percentage, the higher the saving and also the longer the
compressor lifetime.
Press
: Select:
(for 100%),
(for 75%), (for 50%)
When the level is selected, PWR-SEL level
fl
ashes on LCD display for 3
•
seconds. In case of 75% and 50% level, number “75” or “50” also
fl
ashes
for 2 seconds.
Due to the reason that POWER SELECT FUNCTION limits the maximum
•
current, inadequate capacity may occur.
To save energy while sleeping, automatically control air
fl
ow and automatically
turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note:
The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
POWER-SELECTION OPERATION
16
COMFORT SLEEP OPERATION
17
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
20
OPERATION AND PERFORMANCE
21
1. Three-minute protection feature: To prevent the unit from being activated for 3
minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating operation
starts.
3. Warm air control: When the room temperature reaches the set temperature, the fan
speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into the room. When
the outdoor temperature is too low, use another recommended heating apparatus in
combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit where it will
not be subjected to snow drifts, accumulation of leaves or other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal because
the cracking sound may be caused by expansion/contraction of plastic.
Note:
Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room
Temperature
-TR, -A Series
-EE Series
Heating
–15°C ~ 24°C
–20°C ~ 24°C
Less than 28°C
Cooling
–10°C ~ 46°C
21°C ~ 32°C
Dry
–10°C ~ 46°C
17°C ~ 32°C
The unit does not operate.
Cooling or Heating is abnormally low.
The power main switch is
•
turned off.
The circuit breaker is activated
•
to cut off the power supply.
Stoppage of electric current
•
ON timer is set.
•
The
fi
lters are blocked with dust.
•
The temperature has been set improperly.
•
The windows or doors are opened.
•
The air inlet or outlet of the outdoor unit is blocked.
•
The fan speed is too low.
•
The operation mode is FAN or DRY.
•
POWER SELECT FUNCTION is set at 75% or 50%.
•
TROUBLESHOOTING (CHECK POINT)
22
REMOTE CONTROL A-B SELECTION
23
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil.
“00” will be shown on the display.
4. Press
during pushing
. “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized.
Note:
1. Repeat above step to reset
Remote Control to be A.
2. Remote Control A has not “A”
display.
3. Default setting of Remote Control
from factory is A.
1. Press
button to change to 8°C set temperature heating operation.
2. Press
to adjust setting temperature from 5°C to 13°C.
Note:
8°C will operate in Heating mode only. If Air conditioner performs in cooling
operation (including automatic cooling) or dry operation it will change to
heating operating.
8°C OPERATION
18
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the
fi
lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER button on
the remote control.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
•
No benzine, thinner, polishing powder or chemically-treated duster.
•
Cleaning the air ionizer (Once every six months)
1. Turn off air conditioner using remote control and power supply.
2. Fully open the vertical air
fl
ow louvers by hand.
3. Use a toothbrush to rub the ends of metal pin three or four times.
Note:
Do not use cotton swabs or other objects with
fl
uff.
Cleaning the plasma air puri
fi
er unit (About 1000 hours performed)
1. Turn off air conditioner using remote control and power supply.
2. Take out the air inlet grille (See detail in installation manual).
3. Take out the plasma air puri
fi
er by grasp the handle, and the pull it out.
4. Soak in hot water at 40°C to 50°C for about 10 to 15 minutes and rub up, down, left,
right and rub surface gently with a sponge.
5. Allow to dry thoroughly in the shade.
6. Attach the plasma air puri
fi
er by grasp the handle
and insert into the right and left guide rails.
7. Press both ends of the plasma air puri
fi
er until the
protrusions on both sides of the plasma air puri
fi
er
are completely inserted.
8. Attach the air
fi
lter, and then close the air inlet grille.
MAINTENANCE
19
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode, the fan
will continue to run for other 30 minutes, then it will turn off automatically.
This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times within 30
seconds.
EN