7

OTHERS

OTHERS

Gas Leak Test

Test Operation

To switch the TEST RUN (COOL) 
mode, press RESET button for 
10 seconds. (The beeper will 
make a short beep.)

Auto Restart Setting

The product was shipped with Auto Restart function in the off position. 
Turn it on as required.

Remote Control A-B Selection

Note :  1.  Repeat above step to reset Remote Control to be A.
 

 

2.  Remote Control A have not “A” display.

 

 

3.  Default setting of Remote Control from factory is A.

To separate using of remote control for each indoor unit in case of 2 air 
conditioner are installed near.

Remote Control B Setup.

1.  Press RESET button on the indoor unit to turn the air conditioner ON.
2.  Point the remote control at the indoor unit.
3.  Push and hold 

 button on the Remote Control by the tip of the pencil. 

“00” will be shown on the display.

4. Press 

 during pushing 

. “B” will show on the display and “00” will 

disappear and the air conditioner will turn OFF. The Remote Control B is 
memorized.

•  When two indoor units are installed in the same room or adjacent two 

rooms, if operating a unit, two units may receive the remote control signal 
simultaneously and operate. In this case, the operation can be preserved 
by setting either one remote control to B setting. (Both are set to A setting 
in factory shipment.)

•  The remote control signal is not received when the settings of indoor unit 

and remote control are different.

•  There is no relation between A setting/B setting and A room/B room when 

connecting the piping and cables.

This product is designed so that, after a power failure, it can restart 
automatically in the same operating mode as before the power failure.

RESET

Hi POWER  FILTER         PAP         TIMER    OPERATION

RESET button

     

Stripping length of the connecting cable

Model

 10, 13, 16SKVP2 Series,

25, 35, 45SKVP2 Series

Power source

50Hz, 220 – 240 V Single phase

Maximum running current

11A

Plug socket & fuse rating

15A

Power cord

H07RN-F or 245 IEC66 (1.5 mm

2

 or more)

 

NOTE

       

: Connecting cable

•  Wire type : More than H07RN-F or 245 IEC66 (1.0 mm

2

 or more).

•  Wrong wiring connection may cause some electrical parts burn out.
•  Be sure to comply with local cords on running the wire from indoor unit 

to outdoor unit (size of wire and wiring method, etc.).

•  Every wire must be connected 

fi

 rmly.

•  This installation fuse (15A) must be used for the power supply line of 

this air conditioner.

•  If incorrect or incomplete wiring is carried out, it will cause an ignition or 

smoke.

•  Prepare the power supply for exclusive use with the air conditioner.
•  This product can be connected to the mains.
 Connection to 

fi

 xed wiring: A switch which disconnects all poles and 

has a contact separation of at least 3 mm must be incorporated in the 

fi

 xed wiring.

CAUTION

Check places for
the indoor unit.

Electric parts 
cover

Check places for
the outdoor unit.

Valve cover

Information

0

1

0

1

0

1

0

1

30

30

40

40

L N

1 2 3

1

2

L

N

3

Connecting cable

Power cord

Earth line

Earth line

Connecting 

cable

Terminal 

block

Power 
cord

• Check the 

fl

 are nut 

connections for the gas 
leak with a gas leak 
detector or soap water.

Wiring Connection

1.  Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminals as identi

fi

 ed with their 

respective matched numbers on the terminal block of indoor and outdoor 
unit.

3.  When connecting the connecting cable to the outdoor unit terminals, make 

a loop as shown in the installation diagram of indoor and outdoor unit to 
prevent water coming in the outdoor unit.

4. Insulate the unused cords (conductors) from any water coming in the 

outdoor unit. Proceed them so that they do not touch any electrical or metal 
parts.

      

How to set the Auto Restart

1.  Press and hold the RESET button on the indoor unit for 3 seconds to set 

the operation (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds).

2.  Press and hold the RESET button on the indoor unit for 3 seconds to 

cancel the operation (3 beep sound but OPERATION lamp does not 
blink).

 

•  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION 

does not activate.

1110251240-EN.indd   7

1110251240-EN.indd   7

4/19/11   2:07:21 PM

4/19/11   2:07:21 PM

Summary of Contents for RAS-16SAVP2 Series

Page 1: ...AL Indoor unit RAS 10 13 16SKVP2 Series RAS 25 35 45SKVP2 Series Outdoor unit RAS 10 13 16SAVP2 Series RAS 25 35 45SAVP2 Series 1110251240 ENGLISH PУCСКИЙ TÜRKÇE Cover 1110251240 indd 1 Cover 1110251240 indd 1 4 5 11 5 19 47 PM 4 5 11 5 19 47 PM ...

Page 2: ...onte edilmesi 4 İç Ünitenin Takılması 5 Su Boşaltma 5 DIŞ ÜNİTE 5 Montaj Yeri 5 Soğutma Maddesi Boru Bağlantısı 6 Boşaltma 6 Kablo Bağlantısı 7 DİĞERLERİ 7 Gaz Kaçağı Testi 7 Uzaktan Kumanda ile A B Seçimi 7 Test İşlemi 7 Otomatik Yeniden Başlama Ayarı 7 İÇİNDEKİLER TR MEPЫ БEЗOПACHOCTИ 1 СХЕМА УСТАНОВКИ ВНУТРЕННЕГО И НАРУЖНОГО БЛОКОВ 2 Oпционaльныe Уcтaновочныe Чacти 2 BHУTPEHHИЙ БЛOК 3 Mecто Уcт...

Page 3: ...ting machine oil the sizes of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials with highpressure withstand capabilities designed for R410A only and ensure that water or dust does not enter Moreover do not use any existing piping as its press...

Page 4: ...hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Pan head wood screw Remote control holder Vinyl tape Apply after carrying out a drai...

Page 5: ...es near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote...

Page 6: ...n cut them with a pair of nippers or an equivalent tool Slit Slit Left hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall surface If the connecting pipe is laid exceeding 43 mm above the wall surface the indoor unit may unstably be set on the wall When bending the connecting pipe make sure to use a spring bender so as not to crush the pipe Bend the ...

Page 7: ...TE The hole should be made at a slight downward slant on the outdoor side 50 mm or more Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Do not form the drain hose into a wavy shape Do not rise the drain hose Extension drain hose Inside the room Drain hose Shield pipe Arrange the drain pipe for proper drainage from the unit Improper drainage can result i...

Page 8: ...e Flaring Be sure to use a vacuum pump with counter flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops If oil inside of the vacuum pump enters the air conditioner which use R410A refrigeration cycle trouble may result 1 Connect the charge hose from the manifold valve to the service port of the packed valve at gas sid...

Page 9: ...6 1 5 mm2 or more NOTE Connecting cable Wire type More than H07RN F or 245 IEC66 1 0 mm2 or more Wrong wiring connection may cause some electrical parts burn out Be sure to comply with local cords on running the wire from indoor unit to outdoor unit size of wire and wiring method etc Every wire must be connected firmly This installation fuse 15A must be used for the power supply line of this air c...

Page 10: ...Cover back 1110251240 indd 1 Cover back 1110251240 indd 1 4 5 11 5 19 32 PM 4 5 11 5 19 32 PM ...