Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both con-

necting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

1.  Die-cutting front panel slit

  Cut out the slit on the leftward or right side of the front panel for the left or 

right connection and the slit on the bottom left or right side of the front panel 
for the bottom left or right connection with a pair of nippers.

2.  Changing drain hose

 

For leftward connection, bottom-leftward connection and rearleftward 
connection’s piping, it is necessary to change the drain hose and drain 
cap.

How to remove the drain cap

Clip the drain cap by needle-
nose pliers and pull out.

Heat insulator

Drain hose

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges of steel plate. The edges can injuries.

•  To install the drain hose, insert the drain hose 

fi

 rmly until the connection part contacts with heat 

insulator, and the secure it with original screw.

How to 

fi

 x the drain cap

1) Insert hexagon 
 

wrench (4 mm) 

 

in a center head.

4 mm

2)  Firmly insert the drain cap.

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage of the plug.

Insert a hexagon
wrench (4 mm).

No gap

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  After scribing slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

In case of bottom right or bottom left piping

•  After scribing slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

Slit

Slit

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 43 mm above the wall 

surface. If the connecting pipe is laid exceeding 43 mm above the wall 
surface, the indoor unit may unstably be set on the wall.

  When bending the connecting pipe, make sure to use a spring bender so as 

not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (

fi

 gure)

How to install the air inlet grille on the indoor 
unit

•  When attaching the air inlet grille, 

the contrary of the removed 
operation is performed.  

Wiring Connection

Wiring of the connecting cable can be carried out without removing the 
front panel.

1.  Remove the air inlet grille.
 

Open the air inlet grille upward and pull it toward you.

2.  Remove the terminal cover and cord clamp.
3.  Insert the connecting cable (according to the local cords) into the pipe hole 

on the wall.

4.  Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 15 cm from the front.

5.  Insert the connecting cable fully into the terminal block and secure it tightly 

with screws.

6.  Tightening torque : 1.2 N·m (0.12 kgf·m)
7.  Secure the connecting cable with the cord clamp.
8.  Fix the terminal cover, rear plate bushing and air inlet grille on the indoor 

unit.

     

How to connect the connecting cable

•  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

•  Check local electrical cords and also any speci

fi

 c wiring instructions or 

limitations. 

 

NOTE

•  Use stranded wire only.
•  Wire type : More than H07RN-F or 245 IEC66 (1.0 mm

2

 or more).

CAUTION

CAUTION

10 mm

10 mm

50 mm 

110 mm

Cord clamp

Terminal block

Terminal cover

Screw

Earth line

Screw

Connecting cable

Screw

Earth line

Connecting cable

Stripping length of the connecting cable

about 15 cm

80

270 mm

230 mm

m

3

4

Liquid side

Gas side

(To the forefront of 

fl

 are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)

Use the handle of screwdriver, etc.

1110251240-EN.indd   4

1110251240-EN.indd   4

4/19/11   2:07:20 PM

4/19/11   2:07:20 PM

Summary of Contents for RAS-16SAVP2 Series

Page 1: ...AL Indoor unit RAS 10 13 16SKVP2 Series RAS 25 35 45SKVP2 Series Outdoor unit RAS 10 13 16SAVP2 Series RAS 25 35 45SAVP2 Series 1110251240 ENGLISH PУCСКИЙ TÜRKÇE Cover 1110251240 indd 1 Cover 1110251240 indd 1 4 5 11 5 19 47 PM 4 5 11 5 19 47 PM ...

Page 2: ...onte edilmesi 4 İç Ünitenin Takılması 5 Su Boşaltma 5 DIŞ ÜNİTE 5 Montaj Yeri 5 Soğutma Maddesi Boru Bağlantısı 6 Boşaltma 6 Kablo Bağlantısı 7 DİĞERLERİ 7 Gaz Kaçağı Testi 7 Uzaktan Kumanda ile A B Seçimi 7 Test İşlemi 7 Otomatik Yeniden Başlama Ayarı 7 İÇİNDEKİLER TR MEPЫ БEЗOПACHOCTИ 1 СХЕМА УСТАНОВКИ ВНУТРЕННЕГО И НАРУЖНОГО БЛОКОВ 2 Oпционaльныe Уcтaновочныe Чacти 2 BHУTPEHHИЙ БЛOК 3 Mecто Уcт...

Page 3: ...ting machine oil the sizes of charging port connecting sections on the main unit are different from those for the conventional refrigerant and different size tools are also required For connecting pipes use new and clean piping materials with highpressure withstand capabilities designed for R410A only and ensure that water or dust does not enter Moreover do not use any existing piping as its press...

Page 4: ...hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat resisting polyethylene foam 1 Batteries Pan head wood screw Remote control holder Vinyl tape Apply after carrying out a drai...

Page 5: ...es near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote...

Page 6: ...n cut them with a pair of nippers or an equivalent tool Slit Slit Left hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall surface If the connecting pipe is laid exceeding 43 mm above the wall surface the indoor unit may unstably be set on the wall When bending the connecting pipe make sure to use a spring bender so as not to crush the pipe Bend the ...

Page 7: ...TE The hole should be made at a slight downward slant on the outdoor side 50 mm or more Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Do not form the drain hose into a wavy shape Do not rise the drain hose Extension drain hose Inside the room Drain hose Shield pipe Arrange the drain pipe for proper drainage from the unit Improper drainage can result i...

Page 8: ...e Flaring Be sure to use a vacuum pump with counter flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops If oil inside of the vacuum pump enters the air conditioner which use R410A refrigeration cycle trouble may result 1 Connect the charge hose from the manifold valve to the service port of the packed valve at gas sid...

Page 9: ...6 1 5 mm2 or more NOTE Connecting cable Wire type More than H07RN F or 245 IEC66 1 0 mm2 or more Wrong wiring connection may cause some electrical parts burn out Be sure to comply with local cords on running the wire from indoor unit to outdoor unit size of wire and wiring method etc Every wire must be connected firmly This installation fuse 15A must be used for the power supply line of this air c...

Page 10: ...Cover back 1110251240 indd 1 Cover back 1110251240 indd 1 4 5 11 5 19 32 PM 4 5 11 5 19 32 PM ...