6
EN
• A place which provides enough space around the indoor unit as shown in the diagram. (
)
see page 3.)
• A place where there are no obstacles near the air inlet and outlet.
• A place which allows easy installation of the piping to the outdoor unit.
• A place which allows the front panel to be opened.
• The indoor unit shall be installed so that the top of the indoor unit is positioned at least 2 m high.
Also, avoid putting anything on the top of the indoor unit.
Remote controller
• Should be placed where there are no obstacles, such as curtains, that may block the signal.
• Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove.
• Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment. (This is necessary to prevent image
disturbance or noise interference.)
• The location of the remote controller should be determined as shown below.
Drilling
When installing the refrigerant pipes from the rear.
1.
Decide the installation plate mounting position on the wall.
2.
Mark the corresponding pipe hole wall positions according to the positioning marks (
) on the installation plate.
3.
Drill the pipe holes (
φ
65 mm) slightly slanted downward to the outside.
NOTE
• When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately.
4 INSTALLATION OF INDOOR UNIT
Installation Location
CAUTION
• Direct sunlight on the indoor unit wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to r-f sources.
(For details, see the owner’s manual.)
Drilling and Mounting Installation Plate
Indoor unit
(Top view)
(Side view)
Remote
controller
Reception
range
Remote controller
Ind
oor
u
nit
*: Axial distance
Reception
range
42 mm
65 mm
The center of the
pipe hole
Pipe
hole
InstallationManual.book Page 6 Tuesday, January 9, 2007 3:22 PM