background image

SWING

FAN

FIX

QUIET

Hi POWER

ONE-TOUCH

COMFORT

SLEEP

1

#

4

6
5
(

%

"
9
!
-
~

2
3
7
$
&

8
)
,
+

PREPARATION BEFORE USE

2

Preparing Filters

1. Open the air inlet grille and remove the air 

fi

 lters.

2. Attach the 

fi

 lters. (see detail in the accessory sheet).

Loading Batteries (when use wireless operation.)

1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) 

following the (+) and (–) positions.

Clock Setup

1. Push 

 by tip of the pencil.

If timer indication is 

fl

 ashing, go to the next step 2.

2. Press 

 or 

: adjust the time.

3. Press 

 : Set the time.

Remote Control Reset

Push 

 by tip of the pencil or

1. Remove the batteries.

2. Press 

.

3. Insert the batteries.

AIR FLOW DIRECTION

Note:

•  The provided Remote Controller is a wireless type, which also can be 

used as a wire. Please see “How to Connect The Remote Controller 
for Wired Operation”, located in installation instruction, in case of wired 
control is required.

•  In wire operation, remote controller will return to initial condition 

(PRESET, TIMER and CLOCK will return to initial condition) when user 
shutdown power supply of Air conditioner.

REMOTE CONTROL

4  

1

Infrared signal emitter

2

Start/Stop button

3

Mode select button (MODE)

4

Temperature button (TEMP)

5

Fan speed button (FAN)

6

Swing louver button (SWING)

7

Set louver button (FIX)

8

On timer button (ON)

9

Off timer button (OFF)

!

Setup button (SET)

"

Clear button (CLR)

#

Memory and Preset button (PRESET)

$

One-Touch button (ONE-TOUCH)

%

High power button (Hi-POWER)

&

Economy button (ECO)

(

Quiet button (QUIET)

)

Comfort sleep button (COMFORT SLEEP)

~

Filter reset button (FILTER)

+

Set clock button (CLOCK)

,

Check button (CHECK)

-

Reset button (RESET)

ONE-TOUCH

5

Press the “ONE-TOUCH” button for fully automated operation that is 
customized to the typical consumer preferences in your region of the world. 
The customized settings control temperature air 

fl

 ow strength, air 

fl

 ow 

direction and other settings to provide you alternate contact with “ONE-
TOUCH” of the button. If you prefer other settings you can select from the 
many other operating functions of your Toshiba unit.

Press 

21(728&+

 : Start the operation.

AUTOMATIC OPERATION

6

To automatically select cooling, heating or fan only operation

1.  Press 

02'(

 : Select A.

2.  Press 

 : Set the desired temperature.

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

 or HIGH 

.

DRY OPERATION

8

For dehumidi

fi

 cation, a moderate cooling performance is controlled 

automatically.

1. Press 

02'(

 : Select Dry  .

2. Press 

 : Set the desired temperature.

Hi-POWER OPERATION

9

To automatically control room temperature and air

fl

 ow for faster cooling or 

heating operation (except in DRY and FAN ONLY mode)

Press 

+L32:(5

: Start and stop the operation.

ECO OPERATION

10

To automatically control room to save energy (except in DRY and FAN ONLY 
mode)

Press 

 : Start and stop the operation.

Note:

 Cooling operation; the set temperature will increase automatically 1 

degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperature will decrease.

TEMPORARY OPERATION

11

In case of the misplaced or discharged remote control

•  Pressing the RESET button, the unit can start or 

stop without using the remote control.

•  

Operation mode is set on AUTOMATIC operation, 
preset temperature is 24°C and fan operation is 
automatic speed.

TIMER OPERATION

12

Set the timer when the air conditioner is operating.

Setting the ON Timer

Setting the OFF Timer

1

Press 

  : Set the desired ON 

timer.

Press 

  : Set the desired 

OFF timer.

2

Press 

  : Set the timer.

Press 

  : Set the timer.

3

Press 

  : Cancel the timer.

Press 

  : Cancel the timer.

Daily timer allows the user to set both the ON & OFF timers and will be 
activated on a daily basis.

1

Press 

),;

 : Move the louver in 

the desired vertical direction.

2

Press 

6:,1*

 : Swing the air 

automatically and press again to stop.

3

For horizontal direction, adjust 
manually.

Note:

•  Do not move the louver manually by others.
•  The louver may automation positioning by some operation mode.

INDOOR UNIT DISPLAY

1

 

Display brightness can be adjusted, follow procedure on 

$

.

1

2

3

4

1

Eco (White)

2

Hi-Power (White)

3

Timer (White)

4

Operation mode
- Cool (Blue)
- Heat (Orange)

1. Press 

02'(

 : Select Cool 

, Heat 

 or Fan only 

.

2. Press 

 : Set the desired temperature.

  Cooling: Min. 17°C, Heating: Max. 30°C, 

Fan Only: No temperature indication

3. Press 

)$1

 : Select AUTO, LOW  , LOW+ 

, MED 

MED+ 

 or HIGH 

.

COOLING / HEATING / FAN ONLY OPERATION

7

Summary of Contents for RAS-16PKVSG-E

Page 1: ...ENGLISH ENGLISH 1118350294 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 10 13 16PKVSG E Outdoor unit RAS 10 13 16PAVSG E OWNER S MANUAL R32 ...

Page 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of ex...

Page 3: ...appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 2 5 m CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or ...

Page 4: ...21 728 Start the operation AUTOMATIC OPERATION 6 To automatically select cooling heating or fan only operation 1 Press 02 Select A 2 Press Set the desired temperature 3 Press 1 Select AUTO LOW LOW MED MED or HIGH DRY OPERATION 8 For dehumidification a moderate cooling performance is controlled automatically 1 Press 02 Select Dry 2 Press Set the desired temperature Hi POWER OPERATION 9 To automatic...

Page 5: ...re turned off All turned off In the examples of and the lamp illuminates for 5 seconds before going off SELF CLEANING OPERATION COOL AND DRY OPERATION ONLY 19 To protect bad smell caused by the humidity in the indoor unit 1 If the button is pressed once during Cool or Dry mode the fan will continue to run for other 30 minutes then it will turn off automatically This will reduce the moisture in the...

Page 6: ...1118350294 ...