PRECAUTIONS FOR SAFETY

 

Do not use means to accelerate the defrosting process or to clean, other than 

those recommended by the manufacturer.

 

The appliance shall be stored in a room without continuously operating ignition 

sources (for example: open 

fl

 ames, an operating gas appliance or an operating 

electric heater).

 

Be aware that refrigerants may not contain an odour.

 

Do not pierce or burn as the appliance is pressurized. Do not expose the 

appliance to heat, 

fl

 ames, sparks, or other sources or ignition. Else, it may 

explode and cause injury or death.

 

Appliance and pipe-work shall be installed, operated and stored in a room with 

fl

 oor area larger than A

min

 m

2

.

How to get A

min

 m

2

 : A

min

 = (M / (2.5 x 0.22759 x h

0

))

2

M is the refrigerant charge amount in appliance in kg. h

0

 is the installation height 

of the appliance in m: 0.6 m for 

fl

 oor standing/1.8 m for wall mounted/1.0 m 

for window mounted/2.2 m for ceiling mounted. (For these units recommend 

installation height 2.5 m)

 CAUTION

 

Do not wash the unit with water. It may cause an electric shock.

 

Do not use this air conditioner for other purposes such as preserving food, 

breeding animal, etc.

 

Do not step or put anything on the indoor/outdoor unit. It may cause an injury or 

damage the unit.

 

Do not touch aluminium 

fi

 n because it may cause an injury.

 

Before cleaning the unit, turn off the main switch or the circuit breaker.

 

When the unit won’t be used for a long time, turn off the main switch or the 

circuit breaker.

 

It is recommended that maintenance be performed by a specialist when the unit 

has been operated for a long time.

 

The manufacturer shall not assume any liability for the damage caused by not 

observing the description of this manual.

EN

Summary of Contents for RAS-16PKVSG-E

Page 1: ...ENGLISH ENGLISH 1118350294 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS 10 13 16PKVSG E Outdoor unit RAS 10 13 16PAVSG E OWNER S MANUAL R32 ...

Page 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of ex...

Page 3: ...appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 2 5 m CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or ...

Page 4: ...21 728 Start the operation AUTOMATIC OPERATION 6 To automatically select cooling heating or fan only operation 1 Press 02 Select A 2 Press Set the desired temperature 3 Press 1 Select AUTO LOW LOW MED MED or HIGH DRY OPERATION 8 For dehumidification a moderate cooling performance is controlled automatically 1 Press 02 Select Dry 2 Press Set the desired temperature Hi POWER OPERATION 9 To automatic...

Page 5: ...re turned off All turned off In the examples of and the lamp illuminates for 5 seconds before going off SELF CLEANING OPERATION COOL AND DRY OPERATION ONLY 19 To protect bad smell caused by the humidity in the indoor unit 1 If the button is pressed once during Cool or Dry mode the fan will continue to run for other 30 minutes then it will turn off automatically This will reduce the moisture in the...

Page 6: ...1118350294 ...

Reviews: