17
−
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
FILE NO. SVM-12059
No.
1
Reactor
2
Outdoor fan motor
DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k (25°C)
4 Discharge temp. sensor (TD sensor)
62k (20°C)
5 Outside air temp. sensor (TO sensor)
10k (25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k (25°C)
7
Terminal block (5P)
20A, AC250V
9 Coil for PMV
DC12V
10 Coil for 4-way valve
AC220-240V
CAM-MD12TCTH-5
STF
Compressor 3-phases 4-poles 1100W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA131S1B-31FZ
Parts name
Model name
Rating
ICF-140-43-4R
L = 10mH, 16A
CH-57
No.
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3 Heat exchanger temp. sensor (TC-sensor) 10k
Ω
at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
( - )
(
-
)
MSBPC20F04
AC240V, 20W
Part s n ame
1
Specif icat io ns
Type
MF-340-30-3
Ω
Ω
Ω
Ω