−
1
4
−
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling Compressor
Heat exchanger
Propeller fan
Outdoor unit
Capillary tube
∅
1.
7
x
7
00
PA150X2
C
-4F
T
Cooling
Mark( )means check points of Gas Leak.
O.D.:12.7mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
12.7)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
12.7
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410A : 0.9
8
kg.
5-
2
. RAS-13
G
KP-
ES2
/ RAS-13
GA-ES2
Note :
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard 0.
8
0
10
.0 High 27/19 35/24
Cooling Overload 1.
04
1
5
.0 High 32/23 43/26
Low temperature 0.7
2
2.0 Low 21/15 21/15
Fan speed
(indoor)
50Hz
Standar d
pressure P
(MPaG)
Surface temp. of heat
exchang er inter changing
pipe T1 (°C)
l
FILE NO. SVM-06027
Accumulator
RAS-13
N
KP-
AS2
/ RAS-13
N2A-AS2