−
1
2
−
4-
4
.
Outdoor Unit (RAS-1
3GA-ES2, RAS-13N2A-AS2)
No.
Parts name
T
ype
Specifications
Output (Rated)
1100
W, 2poles, 1 phase, 220
−
240V, 50Hz
1 Compressor
PA1
50
X
2
C-4F
T
Winding resistance (
Ω
) C-R C-S
(at 20°C)
2
.
3
5
3
.
22
Output (Rated)
3
0W, 6poles, 1 phase, 220
−
240V, 50Hz
2
F
an motor
(f
or outdoor)
WL
F-240-
3
0
A
Winding resistance (
Ω)
Red-Black White-Black
(at 20°C)
237
380
3
Running capacitor
DS451155NPQB
AC 450V, 1.5
µ
F
(for fan motor)
4
Running capacitor
RS44B306U0214S
A
C 440V
,
30
µ
F
(for compressor)
4-
3
. Indoor Unit (RAS-13
G
KP-
ES2
, RAS-1
3N
KP-
AS2)
FILE NO. SVM-06027
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Transformer
4 Microcontroller unit (IC30) TMP87CM40AN
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600 V
8 Capacitor (C50) PF1E222MNN1625
2200
m
F, 25 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22)
TND
15G561K
560 V
1
1
Louver motor MP24
Z
12VDC
1
2
Relay (Comp., RY01)
DI1U
Rating 2
5
A/AC250 V,
3~48
VDC
W
°
°
°
W
TT-10