10. INSTALLATION PROCEDURE
10-1. Installation Diagram of Indoor and Outdoor Units
FILE NO. SVM-08011
(A
ttach
to the f
ron
t panel)
2
Wireless remote control
5
Super Sterilizer
filter
Super Oxi
Deo filter
6
or bottom left.
Insulate the refrigerant pipes
separately with insulation, not
together.
8
4
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
For the rear left and left piping
Wall
Make sure to run the drain hose
sloped downward.
Do not allow the drain hose to
get slack.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be
connected to the left, rear left,
rear right, right,bottom right
Right
Rear
right
Bottom
right
Rear
left
Bottom left
Left
6 mm thick heat resisting
polyethylene foam
1
Pan head
wood screw
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
Saddle
Extension
drain hose
(Not available,
provided by installer)
Shield pipe
Air filter
Hook
Installation
plate
Hook
65 mm or more
170 mm or more
170 mm or more
600 mm or more
100 mm or m
ore
100
mm
or more
600
mm o
r more
600 mm or more
– 49 –
Before installing the
wireless remote control
.
With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
Wireless remote control
3
Batteries