FILE NO. SVM-05026
together with the timer OFF function. Each
time of pressing [COMFORT SLEEP] button
the off timer setting changes in the sequence
of 1, 3, 5 or 9 hours.
(9) Hi POWER operation control.
When the [Hi POWER] button is pushed
Hi Power operation is performed by change
set temperature and air flow (display on the
remote control does not change).
(8) COMFORT SLEET operation control.
When the [COMFORT SLEEP] button is
pushed, the ECONO operation activate
Fig. 8-2-5
1) Changing of set temperature.
−
27
−
Time (min)
Hi Power
Start
60 and After
45
Set
ting t
empe
ra
tu
re dr
op
(
o
C)
-4.5
-4.0
-2.0
-2.5
-3.0
-3.5
15
30
2) Changing of air flow (Fan setting : AUTO)
When the Hi POWER is started, the fan of the
indoor unit operates at higher air flow level than
normal air flow AUTO (normal air flow AUTO is
shown in Fig. 8-2-1). Because of the difference
between room temperature and set temperature
3) Changing of air flow (Fan setting : One of 5 levels)
When the Hi POWER is started, the fan of the
indoor unit operates at higher consecutive air
flow level. (Fan speed on the display of remote
control does not change)
(10) QUIET operation control.
When the [QUIET] button is pushed, the fan is
restricted the revolution speed at L- level until
the [QUIET] button is pushed once again
(
cancel QUIET operation).
Remarks :
QUIET operation is appropriate to work with
less cooling load condition. Because of the fan
speed L- may cause not enough the cooling
capacity.
are increased automatically.
4) Changing of louver positing
If the room temperature is higher than setting
temperature by 3.5 °C or more, the louver is
automatically set to the maximum air flow
position. If it is not, position of louver is not
change. When room temperature is reach to
setting temperature. The louver moves back
to set position.