![Toshiba RAS-07S2AX Service Manual Download Page 49](http://html.mh-extra.com/html/toshiba/ras-07s2ax/ras-07s2ax_service-manual_1135521049.webp)
−
48
−
9-6-
3
. How to shorten time of restart delay timer
1 Press [CLR] button while pressing [CHK] button
with a tip of a pencil.
2 Then press [
START/STOP]
signal to the indoor unit.
Table 9-6-
3
Approximate resistance value of thermo sensor
Temperature
0°C
10°C
20°C
25°C
30°C
Resistance value
33.8
20.35
12.59
10.00
7.99
(k
Ω
)
9-6-
4
.
How to set/cancel the self cleaning function
The self cleaning function is set from a factory. To cancel this function, should keep press the
[RESET] button for 20 seconds till can hear the long combination sound and repeat the same
procedure when need to set.
FILE NO. SVM-07021-1
MODE
AUTO
COOL
FAN
TEMP.
TEMP.
START/STOP
SWING
MODE
TIMER
ON
OFF
SET
CLR
ECO
RST CHK
FIX
FAN
AUTO
QUIET
AUTO FAN
DRY
Hr.ON OFF
2
1