![Toshiba RAS-07S2AX Service Manual Download Page 4](http://html.mh-extra.com/html/toshiba/ras-07s2ax/ras-07s2ax_service-manual_1135521004.webp)
–
3
–
FILE NO. SVM-07021
540
1. SPECIFICATIONS
MODE L
RA S-07SKSX / RA S-07S2AX
RA S-09SKSX / RA S-09SASX
IT E M
Cooling
Capacity
220V
240V
220V
240V
kW
2.00
2.00
2.50
2.50
Phase
1
Power source
V
220 - 240
Hz
50
Power consumption
kW
0.62
0.66
0.84
0.88
Power factor
%
98
96
98
98
Running
Indoor
A
0.15
current
Outdoor
A
2.72
2.72
3.75
3.60
Starting current A 1
3
15
Moisture removal lit/h 0.
5
1.
2
Noise
Indoor (H/M/L) dB 4
0
/3
5
/3
0
43/38/33
Outdoor dB 4
6
4
7
46 47
Refrigerant
Name of refrigerant
R22
Rated amount kg 0.
58
0.
58
Refrigerant control
Capillary tube
Gas side size
mm
9.52
Connection type
Flare connection
Liquid side size
mm
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m 1
0.0
1
0.0
(One way)
Maximum height
m
5
5
difference
INDOOR UNIT
RA S-07SKSX
RA S-09SKSX
Height
mm
250
Dimensions
Width
mm
740
Depth
mm
185
Net weight
kg
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
Air volume
High fan
m
3
/h
430 4
7
0
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUT DOOR UNIT
RAS-07S2AX
RAS-09SASX
Height mm 5
3
0
Dimensions Width mm
66
0
Depth mm 2
4
0
Net weight kg 2
5
Condenser type
Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1
5
80 1
6
40
Fan motor output
W
20
20
Compressor
Model
PH108X1C-4DZDN2
Output W 605 7
8
0
Safety device
Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range °C
21 ~ 43
1
6
60 1
72
0
8
QK164PBA
30
3
9
0
350
510
Low fan
Medium fan
m
3
/h
m
3
/h