9
-
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-10
S
KHP-E
, RAS-07SKHP-E
)
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) AFS-220-20-4AR AC Motor with 145 °C thermo fuse
2
Thermo sensor (TA-sensor)
10k at 25 C
3 Micro power module (M01) RM1260V
4 Microcontroller unit (IC30)
TMP87CM40AFG-6P69
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
27mH, 600mA
7 Bridge rectifier (DB01) DB105G 1A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 47
m
F, 400 V
9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22)
TND15G-561KB0SLAA0
560 V
11 Resistor (R319) RF-2TK5R6
5.6 , 2 W
12 Louver motor 24BYJ48 12VDC
13 Relay (Comp., RY01) G4A-1A-E-CA Rating 20A/AC250 V, 12VDC
14 Relay (Fan, RY03) G5NB-1A Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
W
W
W
°
°
FILE NO. SVM-07023
4-
2
. Outdoor Unit (RAS-10
S2
AH-E)
SKF-240-20B
No.
235.2
260.1
Parts name
Type
Specifications
Output (Rated) 1000 W, 2 poles, 1 phase, 220
-
240 V, 50Hz
1 Compressor
PH180X1C-4DZDN3
Winding resistance (
) C-R C-S
(at 20 C) 3.33 3.78
Output (Rated) 20 W, 6 poles, 1 phase, 220
-
240 V, 50Hz
2 Fan motor (for outdoor) Winding resistance ( ) Red-Black White-Black
(at 20°C
3
Running capacitor
DS451155NPQB AC 450 V ~, 1.5
m
F
(for fan motor)
W
W
°
4
Running capacitor
RS44B256U0214S
AC
44
0 V
~
,
30
m
F
(for compressor)
5
Overload relay JMRA992
69-9103
U/T :
7.3
A (
8
0
°
C), OPEN : 135±5
°
C, CLOSE : 69±11
°
C
m