–32 –
FILE NO. SVM-07023
8
-2. Installation Diagram of Indoor and Outdoor Units
Shield pipe
Air filter
Hook
Hook
(Attac
h to the fr
ont panel.)
47 mm or more
120 mm or more
1
Installation plate
120 mm or more
2
Wireless remote control
5
6
4
Remote control holder
8
Pan head
wood screw
100 mm or more
45 mm or more
400 mm or more
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
600 mm or more
Extension drain hose
(Not available, provided
by installer)
600 mm or more
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
Wall
Do not allow the drain hose to
get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping
hole sloped
slightly.
For the rear left and left piping
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
The auxiliary piping can be
connected to the left, rear left,
rear right, bottom right or
bottom left.
Rear
left
Left
Bottom left
Rear
right
Bottom right
Before installing the
wireless remote control
•
With the remote control cover
open, load the batteries supplied
correctly, obwerving their
polarity.
2
Wireless remote control
3
Batteries
AC
L
Super Oxi
Deo filter
Super Sterilizer
filter