(1) Operation flow chat.
Descriptions
In case of the first operation, after circuit breaker turns OFF/ON or after reset by case No.
4
-1,
4
-2,
8
and
9
.
The Air-Purifier will operates after 1 hour.
For daily used, without turning OFF circuit breaker, Air-Purifier operates immediately.
By using short timer function of remote control*, Air-Purifier operates immediately.
In case of some error occurs within 1 minute, the above items need to be checked.
Case no
3
, reset by [RESET] button on the indoor unit. Then Air-Purifier will operate again after 1 hour.
Case no
3
, reset by [FILTER] button on the remote control. Then Air-Purifier will operate again after 1 hour.
Case no
3
, reset by turning OFF the unit and turning ON again. Then Air-Purifier operates immediately.
In case of some error occurs after 1 minute. Air-Purifier will turn OFF but in contrast, PAP LED will keep turning
ON continuously.
Case no
5
, the Air-Purifier will operate again after 10 minute.
After complete 500 hours operation, FILTER LED will turn ON and Air-Purifier will turn OFF. In addition, Air-Purifier
should be cleaned.
Case no
7
, reset by [RESET] button on the indoor unit, and Air-Purifier will operate again after 1 hour.
Case no
7
, reset by [FILTER] button on the remote control, and Air-Purifier will operate again after 1 hour.
Case no
7
, can not reset by turning unit OFF and ON.
Case
1
&
2
3
4
-1
4
-2
4
-3
5
6
7
8
9
!
*
Short timer is the function of the remote control that activates the setting for the sudden operation. This
function can be set as shown below.
1. Press [ ] button to turn the unit OFF.
2. Use the tip of the pencil to push the [CHECK] button and hold, “00” will show on display, then press [SET]
button to make “00” disappear.
3. Press [ ] button again to turn the unit ON.
4. When short timer is activated, all setting on the remote operates immediately, Besides, all LED turns ON
continuously for 2 seconds.
PAP
START
OPERATION LED ON
PAP LED ON
Indoor fan ON
1 hour later
Less than 1 hour
Air-Purlfier ON
Air-Purlfier OFF
Operation confirm
Error within 1 minute
Error after 1 minute
10 minutes
No error
500 hours
PAP LED ON
Air-Purifier ON
PAP LED ON
Air-Purifier OFF
FILTER LED ON
Air-Purifier OFF
FILTER LED ON
Air-Purifier OFF
Checking
Air-Purifier insertion
Inlet-Grlll assembly
Micro switch
Hi voltage unit
Reset by
1. [RESET] button
2. [FILTER] button
Reset by
1. [RESET] button
2. [FILTER] button
3. Turn unit OFF/ON
1
5
3
7
8
9
!
4
-3
4
-1 &
4
-2
6
2