6

Drain
guide

Space for pipes

Wall

Shield pipe

Inside the room

Drain hose

Extension drain hose

Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.

This air conditioner has the structure designed 
to drain water collected from dew, which forms 
on the back of the indoor unit, to the drain pan. 
Therefore, do not store the power cord and other 
parts at a height above the drain guide.

CAUTION

OUTDOOR UNIT

OUTDOOR UNIT

Installation Place

•  A place which provides the spaces around the outdoor unit as shown in the 

diagram

•  A place which can bear the weight of the outdoor unit and does not allow an 

increase in noise level and vibration

•  A place where the operation noise and discharged air do not disturb your 

neighbors

•  A place which is not exposed to a strong wind
•  A place free of a leakage of combustible gases
•  A place which does not block a passage
•  When the outdoor unit is to be installed in an elevated position, be sure to 

secure its feet.

•  The allowable pipe length is up to 15 m for RAS-05, 07, 10, 13BAV-E and 

20 m for RAS-16BAV-E.

•  The allowable height of outdoor-unit installation site is up to 12 m.
•  A place where the drain water does not raise any problems

CAUTION

1.  Install the outdoor unit without anything blocking the air discharging.
2.  When the outdoor unit is installed in a place always exposed to strong 

wind like a coast or on a high storey of a building, secure the normal fan 
operation using a duct or a windshield.

3.  In particularly windy areas, install the unit such as to avoid admission of 

wind.

4.  Installation in the following places may result in trouble.
  Do not install the unit in such places.
  •  A place full of machine oil
  •  A saline-place such as the coast
  •  A place full of sul

fi

 de gas

  •  A place where high-frequency 

waves are likely to be generated 
as from audio equipment, welders, 
and medical equipment

Strong 

wind

•  Do not use the supplied drain nipple for draining water. Drain the water 

from all the drain holes directly.

•  To protect the outdoor unit from snow accumulation, install a holding 

frame, and attach a snow protection hood and plate.

*  Do not use a double-stacked design.

Precautions about Installation in Regions

with Snowfall and Cold Temperatures

Snow protection plate

Snow protection hood

Snow accumulation line

Holding frame

At least
50 cm

Install at least 50 cm
above the snow
accumulation line.

Anchor
bolts

Front

Flare at 
indoor unit side

Flare at
outdoor unit side

Flare nut

Half union

Externally
threaded side

Internally
threaded side

Use a wrench to secure.

Use a torque wrench to tighten.

90

Obliquity

Roughness

Warp

CAUTION

Refrigerant Piping Connection

1.  Cut the pipe with a pipe cutter.

2. Insert a 

fl

 are nut into the pipe and 

fl

 are the pipe.

 • 

Projection margin in 

fl

 aring : A (Unit : mm)

RIDGID

 (clutch type)

IMPERIAL

 (wing nut type)

Outer dia. of copper pipe

R410A

Ø6.35

1.5 to 2.0

Ø9.52

1.5 to 2.0

Ø12.70

2.0 to 2.5

Align the centers of the connecting pipes and tighten the 

fl

 are nut as far as pos-

sible with your 

fi

 ngers. Then tighten the nut with a spanner and torque wrench 

as shown in the 

fi

 gure.

     

Tightening connection

Do not apply excess torque. Otherwise, the nut may crack depending on 
the conditions.

(Unit : N·m)

Outer dia. of copper pipe 

Tightening torque

Ø6.35 mm

16 to 18 (1.6 to 1.8 kgf·m)

Ø9.52 mm

30 to 42 (3.0 to 4.2 kgf·m)

Ø12.70 mm

50 to 62 (5.0 to 6.2 kgf·m)

Outer dia.

of copper pipe

R410A tool used

Conventional tool 

used

Ø6.35

0 to 0.5

1.0 to 1.5

Ø9.52

0 to 0.5

1.0 to 1.5

Ø12.70

0 to 0.5

1.0 to 1.5

• 

Tightening torque of 

fl

 are pipe connections

 

The operating pressure of R410A 
is higher than that of R22 (approx. 
1.6 times). It is therefore necessary 
to 

fi

 rmly tighten the 

fl

 are pipe 

connecting sections (which connect 
the indoor and outdoor units) up to the 
speci

fi

 ed tightening torque. Incorrect 

connections may cause not only a 
gas leakage, but also damage to the 
refrigeration cycle.

     Flaring

A

Die

Pipe

2.  Put water in the drain pan and make sure that the water is drained out of 

doors.

3. When connecting extension drain hose, insulate the connecting part of 

extension drain hose with shield pipe.

Summary of Contents for RAS-05, RAS-07

Page 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1118350197 Indoor unit RAS 05 07 10 13 16BKV E Outdoor unit RAS 05 07 10 13 16BAV E ENGLISH ...

Page 2: ... 4 Indoor Unit Fixing 5 Drainage 5 OUTDOOR UNIT 6 Installation Place 6 Precautions about Installation in Regions with Snowfall and Cold Temperatures 6 Refrigerant Piping Connection 6 Evacuating 7 ELECTRICAL WORKS 8 Wiring Connection 8 Power Supply and Connecting Cable Connection 9 Power Supply Input Wiring Diagram 10 OTHERS 11 Gas Leak Test 11 Remote Control A B Selection 11 Test Operation 11 Auto...

Page 3: ...neighbors To avoid personal injury be careful when handling parts with sharp edges Please read this installation manual carefully before installing the unit It contains further important instructions for proper installation The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual Before installation please read these precautions for safe...

Page 4: ... screw 6 6 Flat head wood screw 2 7 Owner s Manual 1 8 Installation Manual 1 Outdoor Unit No Part name No Part name 9 Drain nipple 1 Cap water proof 2 Not require to use for RAS 05 07 10 13BAV E Air filters Clean every 2 weeks 1 Open the air inlet grille 2 Remove the air filters 3 Vacuum or wash and then dry them 4 Reinstall the air filters and close the air inlet grille ...

Page 5: ...it and wall and tilt the indoor unit for better operation For the rear left and left piping Wall Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat ...

Page 6: ...unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed at least 2 5 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e ...

Page 7: ... piping After scribing slits of the back body with a knife or a making off pin cut them with a pair of nippers or an equivalent tool In case of bottom right or bottom left piping After scribing slits of the back body with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In ...

Page 8: ...Drain the water from all the drain holes directly To protect the outdoor unit from snow accumulation install a holding frame and attach a snow protection hood and plate Do not use a double stacked design Precautions about Installation in Regions with Snowfall and Cold Temperatures Snow protection plate Snow protection hood Snow accumulation line Holding frame At least 50 cm Install at least 50 cm ...

Page 9: ...dle of the gauge manifold valve 6 Open fully the valve stem of the packed valves both gas and liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Using a vacuum pump CAUTION KEEP IMPORTANT 5 POINTS FOR PIPING WORK 1 Take away dust and moisture inside of the connecting pipes 2 Tighten the connections between pipes and unit 3 Evacuate the ai...

Page 10: ...tightly with screws 6 Tightening torque 1 2 N m 0 12 kgf m 7 Secure the connecting cable with the cord clamp 8 Fix the terminal cover and air inlet grille on the indoor unit Cord clamp Terminal cover Screw Screws Air inlet grille Front panel 1 Remove the valve cover the electric parts cover and the cord clamp from the outdoor unit 2 Connect the connecting cable to the terminal as identified by the...

Page 11: ...ect to 1 2 3 Terminal block L N 1 2 3 Earth line Power supply cable Connecting cable Earth line Connecting cable Stripping length of the connecting cable 3 50 mm Earth line 10 mm 70 mm 10 mm Power Supply Input at Outdoor Unit Terminal Block Optional Indoor Unit Outdoor Unit Connecting cable connect to L 2 3 Terminal block L N 1 2 3 Earth line Connecting cable Connecting cable Stripping length of t...

Page 12: ...urn out 8 Incorrect or incomplete wiring is carried out it will cause an ignition or smoke 9 This product can be connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram Power supply input at Indoor unit Terminal Block Recommend Indoor Terminal...

Page 13: ...ating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setting B setting and A room B ro...

Page 14: ...ner has a history of the compressor failing and being replaced y When discolored oil a large quantity of residue shiny metal dust or other wear residue or mixture of foreign matter is observed trouble will occur 8 When temporary installation and removal of the air conditioner are repeated such as when leased etc 9 If the type of refrigerator oil of the existing air conditioner is other than the fo...

Page 15: ......

Page 16: ...1118350197 ...

Reviews: