PRECAUTIONS FOR SAFETY

PRECAUTIONS FOR SAFETY

WARNING

•  Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
•  Do not install in a place which cannot bear the weight of the unit.
  Personal injury and property damage can result if the unit falls.
•  Before doing the electrical work, attach an approved plug to the power supply cord.
  Also, make sure the equipment is properly earthed.
•  Appliance shall be installed in accordance with national wiring regulations.
  If you detect any damage, do not install the unit. Contact your dealer immediately.
•  Do not use any refrigerant different from the one speci

fi

 ed for complement or replacement.

  Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your 

body.

DANGER

•  FOR USE BY QUALIFIED PERSONS ONLY.
•  TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF.
  FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
•  CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE 

DAMAGED.

•  CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
•  DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
  FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
•  TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM 

HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.

•  WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED 

REFRIGERANT (R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE 
REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST 
OF THE PIPE AND INJURIES ON PERSONS.

•  IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR 

INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.

CAUTION

•  Exposure of unit to water or other moisture before installation could result in electric shock.
  Do not store it in a wet basement or expose to rain or water.
•  After unpacking the unit, examine it carefully for possible damage.
•  Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and 

discharged air might disturb neighbors.

•  To avoid personal injury, be careful when handling parts with sharp edges.
•  Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
•  The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.

•  Before installation, please read these precautions for safety carefully.
•  Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.

WARNING :

  It indicates that incorrect use of this unit may cause severe injury or death. 

 

CAUTION :

  It indicates that incorrect use of this unit may cause personal injury (*1), or property damage (*2).

 

  *1: Personal injury means a slight accident, burn, or electrical shock which does not require admission or repeated hospital treatment.

 

  *2: Property damage means greater damage which affects assets or resources.

For general public use

Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed 

fl

 exible cord (design H07RN-F) or cord designation 

60245 IEC66. (Shall be installed in accordance with national wiring regulations.)

This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles. 

CAUTION

To disconnect the appliance from the main power supply

New refrigerant air conditioner installation

CAUTION

• 

THIS AIR CONDITIONER USES THE NEW HFC REFRIGERANT (R410A), WHICH DOES NOT DESTROY THE OZONE LAYER.

 

R410A refrigerant is apt to be affected by impurities such as water, oxidizing membranes, and oils because the pressure of R410A refrigerant is approx. 
1.6 times of refrigerant R22. As well as the adoption of this new refrigerant, refrigerating machine oil has also been changed. Therefore, during installation 
work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter the refrigeration cycle of a new-refrigerant air conditioner.

  To avoid mixing refrigerant and refrigerating machine oil, the sizes of charging port connecting sections on the main unit are different from those for the 

conventional refrigerant, and different size tools are also required. For connecting pipes, use new and clean piping materials with high pressure withstand 
capabilities, designed for R410A only, and ensure that water or dust does not enter. Moreover, do not use any existing piping as its pressure withstand 
may be insuf

fi

 cient and may contain impurities.

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems 
or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.

Summary of Contents for RAS-05, RAS-07

Page 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1118350197 Indoor unit RAS 05 07 10 13 16BKV E Outdoor unit RAS 05 07 10 13 16BAV E ENGLISH ...

Page 2: ... 4 Indoor Unit Fixing 5 Drainage 5 OUTDOOR UNIT 6 Installation Place 6 Precautions about Installation in Regions with Snowfall and Cold Temperatures 6 Refrigerant Piping Connection 6 Evacuating 7 ELECTRICAL WORKS 8 Wiring Connection 8 Power Supply and Connecting Cable Connection 9 Power Supply Input Wiring Diagram 10 OTHERS 11 Gas Leak Test 11 Remote Control A B Selection 11 Test Operation 11 Auto...

Page 3: ...neighbors To avoid personal injury be careful when handling parts with sharp edges Please read this installation manual carefully before installing the unit It contains further important instructions for proper installation The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual Before installation please read these precautions for safe...

Page 4: ... screw 6 6 Flat head wood screw 2 7 Owner s Manual 1 8 Installation Manual 1 Outdoor Unit No Part name No Part name 9 Drain nipple 1 Cap water proof 2 Not require to use for RAS 05 07 10 13BAV E Air filters Clean every 2 weeks 1 Open the air inlet grille 2 Remove the air filters 3 Vacuum or wash and then dry them 4 Reinstall the air filters and close the air inlet grille ...

Page 5: ...it and wall and tilt the indoor unit for better operation For the rear left and left piping Wall Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 6 mm thick heat ...

Page 6: ...unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed at least 2 5 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e ...

Page 7: ... piping After scribing slits of the back body with a knife or a making off pin cut them with a pair of nippers or an equivalent tool In case of bottom right or bottom left piping After scribing slits of the back body with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In ...

Page 8: ...Drain the water from all the drain holes directly To protect the outdoor unit from snow accumulation install a holding frame and attach a snow protection hood and plate Do not use a double stacked design Precautions about Installation in Regions with Snowfall and Cold Temperatures Snow protection plate Snow protection hood Snow accumulation line Holding frame At least 50 cm Install at least 50 cm ...

Page 9: ...dle of the gauge manifold valve 6 Open fully the valve stem of the packed valves both gas and liquid sides 7 Remove the charging hose from the service port 8 Securely tighten the caps on the packed valves Using a vacuum pump CAUTION KEEP IMPORTANT 5 POINTS FOR PIPING WORK 1 Take away dust and moisture inside of the connecting pipes 2 Tighten the connections between pipes and unit 3 Evacuate the ai...

Page 10: ...tightly with screws 6 Tightening torque 1 2 N m 0 12 kgf m 7 Secure the connecting cable with the cord clamp 8 Fix the terminal cover and air inlet grille on the indoor unit Cord clamp Terminal cover Screw Screws Air inlet grille Front panel 1 Remove the valve cover the electric parts cover and the cord clamp from the outdoor unit 2 Connect the connecting cable to the terminal as identified by the...

Page 11: ...ect to 1 2 3 Terminal block L N 1 2 3 Earth line Power supply cable Connecting cable Earth line Connecting cable Stripping length of the connecting cable 3 50 mm Earth line 10 mm 70 mm 10 mm Power Supply Input at Outdoor Unit Terminal Block Optional Indoor Unit Outdoor Unit Connecting cable connect to L 2 3 Terminal block L N 1 2 3 Earth line Connecting cable Connecting cable Stripping length of t...

Page 12: ...urn out 8 Incorrect or incomplete wiring is carried out it will cause an ignition or smoke 9 This product can be connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram Power supply input at Indoor unit Terminal Block Recommend Indoor Terminal...

Page 13: ...ating a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setting B setting and A room B ro...

Page 14: ...ner has a history of the compressor failing and being replaced y When discolored oil a large quantity of residue shiny metal dust or other wear residue or mixture of foreign matter is observed trouble will occur 8 When temporary installation and removal of the air conditioner are repeated such as when leased etc 9 If the type of refrigerator oil of the existing air conditioner is other than the fo...

Page 15: ......

Page 16: ...1118350197 ...