Page 10
User Manual
NOTE
¥
delivery lift <1.8m
drain
hose
adaptor
drain
hose
adaptor
X
Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that
there are no kinks that will impede water fl ow. Place the end of the hose into the drain and make sure
the end of the hose is directed downward to let the water fl ow smoothly. (See Figs with
).
Installation not recommended. (See Figs with
X
). When the continuous drain hose is not used,
ensure that the corresponding drain plug and knob are installed fi rmly to prevent leakage.
WATER DRAINAGE (cont.)
•
When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times. The digital display
shows “P1.” At this time the air conditioning/dehumidifi cation
process will immediately stop. However, the fan motor will
continue to operate (this is normal). Carefully move the unit
to a drain location, remove the bottom drain plug and let the
water drain away. Reinstall the bottom drain plug and restart
the machine until the “P1” symbol disappears. If the error
repeats, call for service.
NOTE
Be sure to reinstall the bottom drain plug fi rmly to prevent
leakage before using the unit.