Operations
Warning
Prohibited
Do not apply a dropping shock or other physical shocks.
Otherwise, damage or malfunction will result.
Do not pull on the cable and connector
It may cause damage or error.
Do not bring any regions of your body into contact with the inverter terminals when power is
supplied to the inverter. Contact during the power-on status of the inverter can result in electric
shock.
Mandatory
action
Use an additional safety inverter with your inverter or system to prevent a serious accident due
to the unit malfunctions. Usage without an additional safety inverter may cause an accident.
Make sure to check that the parameter data from this product is not accidently copied to the
wrong inverter.
Usage with wrong parameter may result in an accident.
Caution
▼
Set up “Communication time-out (
f803
,
f804
and
f808
)” (see the inverter instruction
manual for details) to stop the inverter when Parameter writer is deactivated by an unusual
event such as tripping, an operating error, power outage, failure, etc. Deactivated Parameter
writer may cause an accident, if the “Communication time-out” is not properly set up.
Please back up the data used with this unit.
The stored data might be lost according to using condition of the SD card.
Please be forewarned that our company cannot make compensation for the damage depend on
the loss of the stored data.
Mandatory
action
Disposal
Caution
Mandatory
action
If you dispose off this unit, have it done by a specialist in industrial waste disposal*. Improper
disposal may result in explosion of capacitors or produce noxious gases, resulting in injury.
(*) Persons who specialize in the processing of waste and known as “Industrial Waste Product
Collectors and Transporters” or “Industrial Waste Disposal Persons.” If the collection, transport
and disposal of industrial waste is done by someone who is not licensed for that job, it is a
punishable violation of the law (Laws in regard to cleaning and processing of waste materials).
Notes on operation
Notes
Avoid
us
ing in a place where ambient temperature or/and humidity change sharply.
Keep the transmission cable separate from the power cable of the inverter to prevent the
inverter from malfunctioning due to electromagnetic noise.
The integrity of data storage is guaranteed for up to 5 years.
The operating life of the data storage inverter is 10000 operations.
Do not execute more than 10000 writing operations.
Do not turn off power or remove the connection cable between the inverter and Parameter writer
or take off SD card while a copying operation is in progress. If the inverter power is turned off or
the connection cable is removed while parameters are being copied, data cannot be written
correctly.
Do not copy data from Parameter writer to inverter and inverter to Parameter writer while the
inverter is running. Some of the parameters cannot be written when the inverter is in operation.
When a copying operation is executed between two inverters with different capacities, some of
the parameters that vary with the capacity of the inverters will also be copied. Therefore, when
copying the parameters between inverters with different capacities or voltage class, the type
information parameters of the inverter should always be initialized. See the inverter instruction
manual on how to initialize their parameters.