![Toshiba PWU003Z Instruction Manual Download Page 10](http://html.mh-extra.com/html/toshiba/pwu003z/pwu003z_instruction-manual_427143010.webp)
E6581680
3.2. Description
ENT
ESC
H
G
I
J
K
L
D
F
A
E
B
C
M
TOSHIBA
Figure 2
Letter Description
Comments
A
Mini-B USB connector
The connection between the Parameter writer (USB
Mini-B type) and the PC (USB type A) is via a 1 m (3.28
feet) USB type A to Mini-B cable.
B
RJ 45 connector
The connection between the Parameter writer and the
inverter is via a RJ45 cable to load and transfer
configuration files or updated application.
C
RJ11 connector with label cover For factory use only.
D
SD card slot
The SD card receives and stores the files. One SD card is
supplied with the Parameter writer.
E
Battery compartment
It can take 4 normal batteries and rechargeable batteries.
F
Power ON/OFF button
Press for 2 seconds to turn the tool on or off.
G
Quick Store key
Press this key to transfer data from the Parameter writer
to the inverter after an initial transfer in Quick store mode.
H
Screen
The screen comprises 2 lines of 16 characters.
I
ESC key
Returns to the previous screen.
J
ENT key
Confirms the parameter selection or cancels messages.
K
Up arrow key
For menu navigation.
L
Down arrow key
For menu navigation.
M
Holes
For wrist strap
9