 Limitation of use 

 

Safety precaution

 

  Never use this unit with any inverter other than TOSVERT series inverters. Doing so may cause an accident. 

 

 

 Handling in general 

 

Warning

 

 

 

Never 

Disassemble 

 

Never disassemble, modify or repair the product. 
Disassembling the product may cause electric shocks, fire or injuries. 
For repairs, call your sales/repair agency. 

 

 

Prohibited 

 

Do not put or insert foreign objects such as waste cable, bars, or wires into the product.   
It may lead to electric shocks or fire. 

 

Do not splash water over the product, and do not wipe the body with a wet cloth. 
It may lead to electric shocks or fire. 

 

 

Mandatory 

action 

 

Turn off input power before wiring. 
Wait at least 15 minutes and check to make sure that the charge lamp (on the inverter unit) is no 
longer lit. 

 

Turn off the power immediately in case of any abnormalities such as smoke, smell or abnormal 
noise. 
Neglect of these conditions may lead to fire. 
For repairs, call your sales/repair agency. 

 

 Transportation and usage

 

 

Warning

 

 

 

Prohibited 

 

Do not install or operate the inverter if it is damaged or any part of it is missing.   
Operating a defective inverter may lead to electric shocks or fire. 
For repairs, call your sales/repair agency. 

 

Do not put any flammable material near the product. 
It may catch fire due to the product sparking in the case of a malfunction. 

 

Do not connect a LAN cable or telephone modular cable to Parameter writer.   
Doing so may cause a failure or accident.

 

 

  E

lectrical construction work must be done by a qualified expert. 

 

Connection of input power by someone who does not have expert knowledge may result in fire 
or electric shock. 

Mandatory 

action 

 

Operate under the environmental conditions prescribed in the instruction manual.   
Operations under any other conditions may result in malfunction.   

 

An emergency stop inverter must be installed that fits with system specifications 
  (e.g. shut off input power then engage mechanical brake).   
Operation cannot be stopped immediately by the inverter alone, thus risking an accident or 
injury. 

 

Use the attached cable for connecting this optional unit. 
The use of any other option may result in an accident.

 

Caution

 

 

 

Do not use the product in any place subject to vibrations or it may fall.       

 

This may lead to the product falling and causing injury. 

 

Do not use 

nickel-cadmium rechargeable battery or manganese battery

Prohibited 

This may lead to 

liquid spill and fire

 

Do not use different type of battery together, or new battery and reuse one together 

This may lead to 

liquid spill and fire

 

 

Summary of Contents for PWU003Z

Page 1: ...ivered to the end user of the inverter 2 Read this manual before first using the communications function and keep it handy as a reference for maintenance and inspections 3 All information contained in this manual are subject to change without notice Please confirm the latest information on our web site www inverter co jp ...

Page 2: ...to injury 1 to people or that these errors may cause damage to physical property 2 1 Such things as injury burns or shock that will not require hospitalization or long periods of outpatient treatment 2 Physical property damage refers to wide ranging damage to assets and materials Meanings of symbols Marking Meaning of marking Indicates prohibition Don t do it What is prohibited will be described i...

Page 3: ... fire For repairs call your sales repair agency Do not put any flammable material near the product It may catch fire due to the product sparking in the case of a malfunction Do not connect a LAN cable or telephone modular cable to Parameter writer Doing so may cause a failure or accident Electrical construction work must be done by a qualified expert Connection of input power by someone who does n...

Page 4: ... produce noxious gases resulting in injury Persons who specialize in the processing of waste and known as Industrial Waste Product Collectors and Transporters or Industrial Waste Disposal Persons If the collection transport and disposal of industrial waste is done by someone who is not licensed for that job it is a punishable violation of the law Laws in regard to cleaning and processing of waste ...

Page 5: ...ng the configuration to an inverter 14 5 3 Transferring the configuration to more than one inverter using Quick Store 15 6 PARAMETER WRITER MENUS 16 6 1 Parameter writer main menu 16 6 2 Action Load configuration from Parameter writer to inverter 17 6 3 Action Load configuration from inverter to Parameter writer 18 6 4 Quick Store mode 19 6 5 Supervision 20 6 6 Parameter settings Batteries 21 6 7 ...

Page 6: ...ference 1 Receive and inspect the Parameter writer Check that the reference printed on the label is the same as that on the purchase order Remove the Parameter writer from its packaging and check that it has not been damaged in transit 2 Connect the Parameter writer see chapter 4 To a PC To an inverter 3 Copy inverter configurations see chapter 5 Load a configuration onto the Parameter writer Tran...

Page 7: ...ter s SD card See the procedure on section 5 1 B The configuration file is generated by PCM software then transferred to the Parameter writer s SD card See the procedure on section 5 1 1 The user selects and then transfers the configuration file from the Parameter writer to the inverter See the procedure on section 5 2 2 Once the initial transfer is complete the user can use Quick Store mode which...

Page 8: ...y note This should also correspond with the number on the purchase order Contents of the Parameter writer box PWU003Z Check that the Parameter writer box contains the following 1 Parameter writer 2 SD card 3 Standard USB type A to Mini B cable 4 RJ45 RJ45 RJ45 cable Length 1m 5 Carry case 6 User s manual Japanese and English 7 Impact resistant cover 8 Wrist strap 7 ...

Page 9: ...E6581680 3 1 Presentation ENT ESC 65 181 5 27 4 TOSHIBA mm Figure 1 Approximate weight 250 g including batteries 8 ...

Page 10: ...tory use only D SD card slot The SD card receives and stores the files One SD card is supplied with the Parameter writer E Battery compartment It can take 4 normal batteries and rechargeable batteries F Power ON OFF button Press for 2 seconds to turn the tool on or off G Quick Store key Press this key to transfer data from the Parameter writer to the inverter after an initial transfer in Quick sto...

Page 11: ... OFF button See the display parameters menu on section 6 9 Connection to a powered up PC or inverter can also help conserve battery power as the power supply from the connected inverter takes over from the batteries Caution Do not use nickel cadmium rechargeable battery or manganese battery This may lead to liquid spill and fire Mandatory It is not possible occasionally to read according to the ki...

Page 12: ...Parameter writer to avoid an incorrect start up of the PC The SD card must not be removed when the Parameter writer is on and a transfer is in progress Otherwise data on the SD card may be lost The file name length is 255 letters maximum The number of files that can be saved in the SD card is up to 65535 or less N B Too many files cause slow key operation response and display Number of files shoul...

Page 13: ... cable from the inverter B 1 Remove all power from the inverter and all enclosures housing the inverter and wait more than 15 minutes and more to allow the DC bus of the inverter to discharge 2 Insert the Parameter writer s communication cable into the inverter s RJ45 communication port Refer to the inverter s installation manual for more information about how to perform this task 3 Install and cl...

Page 14: ...T when the screen displays Main menu Action 1 Select the Action Config Device MLD menu using the arrow keys and press ENT Device MLD LoadFromDevicexx appears on the screen Press ENT until the transfer starts 2 Load Config Successful The configuration has been loaded successfully onto the Parameter writer disconnect the RJ45 cable from the inverter The inverter configuration file filexx CFG is now ...

Page 15: ...T ENT Action Config XXXXXXXX STEP Procedure 1 Turn the Parameter writer on using the ON OFF button F see section 3 2 Connect the Parameter writer to the inverter using the RJ45 cable see section 4 2 Press ENT when the screen displays Main menu Action Press ENT when the screen displays Action Config MLD Device 2 Select the file to be transferred using the arrow keys and press ENT to start the trans...

Page 16: ...reen displays Main menu Action Press ENT when the screen displays Action Config MLD Device 2 Select the file to be transferred using the arrow keys and press ENT to start the transfer If no inverter is connected a message No device connected appears on the screen see section 6 7 3 The configuration has been transferred successfully from the Parameter writer disconnect the RJ45 cable from the inver...

Page 17: ...functions Load from Parameter writer to inverter Load from inverter to Parameter writer Main menu Device accesses the following information Device type Device version Main menu Parameters accesses Battery parameters Diagnostic parameters Password parameters Display parameters Main menu About MLD accesses Parameter writer version information The Quick Store key see section 3 2 allows the user to tr...

Page 18: ...vice menu accessible from Main menu Action Action Config MLD Device This menu accesses the transfer function for loading configurations from the Parameter writer to the inverter Note Keep on pushing ESC key if the process of searching communication mode is canceled Display is changed faster by keeping on pushing or key 17 ...

Page 19: ... MLD menu accessible from Main menu Action Action Config Device MLD This menu accesses the transfer function for loading configurations from the inverter to the Parameter writer Note Keep on pushing ESC key if the process of searching communication mode is canceled Display is changed faster by keeping on pushing or key 18 ...

Page 20: ... 2 1 The diagram below shows the Quick Store mode which can be accessed after using either of the Action Config MLD Device menus Note 1 Quick Store mode can only be used after an initial transfer to an inverter has been completed Files can only be transferred between inverters with the same reference 19 ...

Page 21: ...ain menu Device This supervisory menu is used to check the reference and version of the inverter connected to the Parameter writer Device Type This menu accesses the reference of the connected inverter Device SW version This menu accesses the software version of the connected inverter 20 ...

Page 22: ...used to select the type of battery used by the Parameter writer normal batteries or rechargeable batteries Users must ensure that the correct battery type is selected so that the Parameter writer can accurately display the charge level This also affects message activation Battery Charge level Battery Alarm level Parameters Battery Alarm level 20 Save the level Charge level 78 Value between 0 and 5...

Page 23: ... transfer to the inverter The inverter is in parameter change prohibition state Load config fault Incomplete or incorrect transfer from the Parameter writer to the inverter The inverter is in parameter read prohibition state Check the RJ45 cable and both of its connectors Make sure the connection is secure for the duration of the transfer Restart the transfer operation Confirm the inverter paramet...

Page 24: ...lay Dis Display Contrast Set contrast 50 Save the contrast Display Backlight Set backlight 3 sec Save the backlight Set backlight 2 sec Display Sleep mode Set sleep mode 05 mn Save the sleep mode Display Language Language English Press and hold the up or down arrow key to define the contrast value more quickly Value between 0 and 100 Set contrast NN Press and hold the up or down arrow key to defin...

Page 25: ...r future inverters 8 Warranty Any part of the unit that is proved to be defective will be repaired free of charge under the following conditions 1 This product will be repaired free of charge if problem fault occurs under normal handling within one year of delivery and is caused obviously by a design or manufacturing defect 2 The warranty applies only to the delivered unit 3 For the following kind...