CUTTING A HOLE AND MOUNTING INSTALLATION
PLATE
Cutting a hole
In case of installing the refrigerant pipes from the
rear:
1. Decide the hole position for piping at
180
mm from the arrow mark (
Ö
) on the
installation plate and drill a hole at a slight
downward slant toward outdoor side. Pipe
hole; dia.65
mm:
8
P015-
8
P018 type Pipe
hole; dia.80
mm:
8
P024 type
80
65
1111012101
80
65
1111012101
180
mm
The center of the pipe hole is above the arrow.
23 mm
dia. 65
mm:
8
P015-
8
P018 type
dia. 80
mm:
8
P024 type
Pipe hole
NOTE
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe
hole brim ring sold separately.
Mounting the installation plate
23
dia.65
mm
132
170
110
120
300
85
Pipe hole
Indoor unit
Hook
Hook
Anchor bolt holes
Thread
Weight
Pipe hole
(dia. 65
mm
dia. 80
mm)
Hook
Installation
plate
Mounting
screw
When the installation plate is
directly mounted on the wall
6HFXUHO\¿WWKHLQVWDOODWLRQSODWHRQWRWKH
wall by screwing it in the upper and lower
parts to hook up the indoor unit.
2. To mount the installation plate on a
concrete wall with anchor bolts, utilize
the anchor bolt holes as illustrated in the
DERYH¿JXUH
3. Install the installation plate horizontally in
the wall.
CAUTION
When installing the installation plate with a
mounting screw, do not use the anchor bolt
hole. Otherwise the unit may fall down and
result in personal injury and property damage.
5
mm dia. hole
Clip anchor
(local parts)
Mounting screw
Anchor bolt
Projection
15
mm or less
NO
GOOD
NO
GOOD
OK
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the unit
falls.
• In case of block, brick, concrete or similar type
walls, make 5
mm dia. holes in the wall.
• Insert clip anchors for appropriate mounting
screws.
NOTE
• Secure four corners and lower parts of the
installation plate with 6 mounting screws to
install it.
%HVXUHWKDWWKHLQVWDOODWLRQSODWHLV¿[WRWKHZDOO
ZLWKVFUHZVWRPDNHWKHLQGRRUXQLW¿WWRWKHZDOO
∅
PP[
s