Installation Manual
18
18-EN
7
INDOOR UNIT FIXING
8
DRAINAGE
1. Pass the pipe through the hole in the wall,
and hook the indoor unit on the installation
plate at the upper hooks.
2. Swing the indoor unit to right and left to
FRQ¿UPWKDWLWLV¿UPO\KRRNHGXSRQWKH
installation plate.
3. While pressing the indoor unit onto the
wall, hook it at the lower part on the
installation plate. Pull the indoor unit
WRZDUG\RXWRFRQ¿UPWKDWLWLV¿UPO\
hooked up on the installation plate.
1
2
Installation plate
Hook here.
Hook
Press
(unhook)
• For detaching the indoor unit from the
installation plate, pull the indoor unit toward
\RXZKLOHSXVKLQJLWVERWWRPXSDWWKHVSHFL¿HG
parts.
Push
Push
1. Run the drain hose sloped downwards.
NOTE
• Hole should be made at a slight downward
slant on the outdoor side.
2. Put water in the drain pan and make sure
that the water is drained out of doors.
3. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with shield pipe.
50 mm
or more
Do not rise the drain hose.
Do not form the drain hose
into a wavy shape.
Do not put the
drain hose end
into water.
Do not put the
drain hose end
in the drainage
ditch.
Drain hose
Extension drain hose
Inside the
room
Shield pipe
CAUTION
Arrange the drain pipe for proper drainage from
the unit.
Improper drainage can result in dew-dropping.
This air conditioner has the structure designed to
drain water collected from dew, which forms on
the back of the indoor unit, to the drain pan.
Therefore, do not store the power cord and other
parts at a height above the drain guide.
Wall
Wall
Space for pipes
Drain guide
Information
The lower part of indoor
unit may float, due to the
condition of piping and
you cannot fix it to the
installation plate. In that
case, use the screws
provided to fix the unit and
the installation plate.
Screw
Screw