69
−
6 F 8 A 0 9 3 4
Switch operation
Display example
Description
STEP5(=END)
R TYPE
2F-2R
SET OK?
When you push , a message appears
to confirm whether the setting is
OK
or not.
If
OK
, push . If you want to redo the
setting, push .
Pushing cancels the setting operation
and exits the setting screen.
●
Changing the span
You can set the span value for each range.
The following is an example to change the span of Range 1 from
2.0 m/s
to
100 L/min
.
Switch operation
Display example
Description
STEP1
R1
2.00000
m/s
Select "
R1
" from the setting item selection
menu.
The currently set span value of Range1
(
2.00000 m/s
in this example) appears.
Then push .
STEP2
R1
2
.00000
m/s
The switches at the bottom change.
( are shown.)
At the same time, the cursor appears.
STEP3
R1
2.00000
m
/s
Push to move the cursor to the digit
of the first unit.
STEP4
R1
3.93000
L
/s
Push to change the first unit.
Push to move the cursor to the
digit of the time unit.
STEP5
R2
236.000
L/
min
Push to change the time unit.
Push to move the cursor to the digit
of span value.
O K
N O
N O
O K
ESC
ESC
ESC