16
Changing the setting in E.TRG mode
(1. 3)
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First move the “
” to MODE and select E. TRG, then move the “
” to E.TRG and select the desired E.TRG mode.
Changing the setting in 1P SNR mode
( 1.3. 1)
SHUTTER
SHUTTER
MODE
E.TRG
E.TRG
1P SNR
TRG.P
EXP.
30ms
OUT.P
OFF
<MODE = E.TRG E.TRG = 1P SNR>
• E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
0.01 ms 0.02 ms 0.4 ms 1 ms 20 ms 30 ms
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
2 ms
step
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity
• Exposure time setting at 1P SNR and 1P SR
• Shutter mode MANU, SS, E.TRG, AUTO
Input trigger pulse : negative polarity
Move up down
by pushing
MENU UP, DOWN
Select the desired
value by pushing
DATA UP, DOWN
• Partial scanning switch
(
PART switch
)
OFF, 40fps, 42fps, 50fps, 60fps, 70fps, 80fps, 90fps
E.40fps, E.42fps, E.50fps, E.60fps, E.70fps, E.80fps, E.90fps
(a) Changing the polarity of the input trigger pulse setting
Move the “
aa
” to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
Select either
aa
,
by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
Move the “
aa
” to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
aa
(c) Changing the partial scanning setting
Move the “
aa
” to OUT.P by pushing [MENU UP], [MENU DOWN] buttons.
Select the mode by pushing [DATA UP], [DATA DOWN] buttons.
aa
Move “
caa
” to the current value by pushing [MENU UP], [MENU DOWN] buttons.
Select a desired settings by pushing [DATA UP], [DATA DOWN] buttons.
daa
* The preset value of partial scanning is not displayed, when OUT.P is OFF.
120730c1_IK_TF7P2_EN.indd 16
12.7.30 1:19:01 PM