background image

 

 
 

 

DRIVE CONNECTORS –MK8026GAX (HDD2191) 

 

 

 

Figure 1.MK8026GAX HDD Rear View - Connectors

 

Interface Connector

 

Drive Side Connector 

Yamaichi GAP050K11617 or equivalent 

Recommended Host Side Connector 

 

Board 

Straight type: Berg 86455-044  86456-044 or equivalent 

Cable 

Berg 89361-044 or equivalent 

Recommended Cable Characteristics

 

Standard diameter 

0.32mm (28AWG) 

Characteristics impedance 

100 - 132ohm 

Max Length 

0.46mm (max) 

Capacitance 35pF 

(max) 

 

* cable is not included with drive

  

Summary of Contents for HDD2191

Page 1: ...TOSHIBA AMERICA INFORMATION SYSTEMS STORAGE DEVICE DIVISION IRVINE CALIFORNIA MK8026GAX HDD2191 2 5 INCH HARD DISK DRIVE USER MANUAL Rev 02 11 2006 ...

Page 2: ...CONTENTS Introduction 1 Setup 2 Using the HDD 4 Troubleshooting 5 Specifications 6 Drive Connectors 8 ...

Page 3: ...zed drive Fluid Dynamic Bearing FDB Motor 2 Platter 80 Gigabytes 9 5mm High 12ms Average Seek Time ATA 2 3 4 5 6 Interface Supports high transfer rates of 100 MB sec 16MB Buffer MTTF 300 000 Hours Toshiba defines a megabyte MB as 1 000 000 bytes and a gigabyte GB as 1 000 000 000 bytes ...

Page 4: ...e configuration only one of each per port is used for two drive applications Use the information in the following table before setting drive as Master or Slave Master configuration is obtained by setting jumpers A B C D open no jumper present Slave configuration is obtained by setting jumpers C D When B D jumper is installed the drive is configured as cable select If pin 28 Low the drive is Master...

Page 5: ...e Avoid touching the interface connector pins and the surface of PCB Be sure to use ESD proof wrist strap when handling drive The four mounting screws should be tightened equally with 0 3N m 3kgf cm torque The depth should be 3 0mm minimum and 3 5mm maximum Placing Hard Drive inside your Computer Determine mounting configuration the drive can be mounted in either a horizontal or vertical orientati...

Page 6: ...4 USING THE HARD DISK DRIVE MK8026GAX HDD2191 Backing up Data Files To avoid data loss regularly back up the data files on the hard disk drive ...

Page 7: ...d party software is available that breaks the capacity barrier Some suggestions are EZ Drive by Micro House and Disk Manager DiskGo by Ontrack Check with your local computer software supplier for availability or contact the software manufacturer How do I install my 2 5 Toshiba Hard Drive into my desktop or tower system You will need a HDD mounting kit in order to install a Toshiba 2 5 drive into y...

Page 8: ...es and a gigabyte GB as 1 000 000 000 bytes Internal Drive Characteristics Number of Disks 2 Number of Read Write Heads 4 Track Density TPI 88k User Data Cylinders 54 000 Logical Cylinders 16 383 Logical Heads 16 Logical Sectors track 63 Bytes per Sector 512 Logical Blocks LBA 156 301 488 Reliability Preventative maintenance None Nonrecoverable read errors 1 error per 1013 bits read Electrical Vol...

Page 9: ...latory The drive satisfies the following standards Underwriters Laboratories UL 1950 Canadian Standard Association CSA C22 2 No 220 No 950 TUV Rheinland EN 60 950 EMC EN50081 1 EN55022 1988 Class B EN60555 2 1987 A1 EN60555 3 77A Co 38 EMC EN50082 1 IEC 801 2 1991 EIC 801 3 1994 IEC 801 4 1988 ...

Page 10: ... GAP050K11617 or equivalent Recommended Host Side Connector Board Straight type Berg 86455 044 86456 044 or equivalent Cable Berg 89361 044 or equivalent Recommended Cable Characteristics Standard diameter 0 32mm 28AWG Characteristics impedance 100 132ohm Max Length 0 46mm max Capacitance 35pF max cable is not included with drive ...

Page 11: ... 2 14 DD 13 15 DD 1 16 DD 14 17 DD 0 18 DD 15 19 GROUND 20 KEY 21 DMARQ 22 GROUND 23 DIOW STOP 24 GROUND 25 DIOR DMARDY HSTROBE 26 GROUND 27 IORDY DMARDY DSTROBE 28 CSEL 29 DMACK 30 GROUND 31 INTRQ 32 IOCS16 33 DA1 34 PDIAG 35 DA0 36 DA 2 37 CS0 38 CS1 39 DASP 40 GROUND 41 5V LOGIC 42 5V MOTOR 43 GROUND 44 RESERVED Note Symbol in front of signal indicates negative logic ...

Reviews: