© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
GD-1150/1151/1200/1201/1160/1260
SPECIFICATIONS AND OUTLINE OF SYSTEM
1 - 3
1
3) Transmission system
Circuits to be used: Subscriber line/FAX communication network (G3)
- Calling automatic transmission (including the sequential multi-address transmission)
- Calling automatic reception (polling reception)
- Called automatic transmission (polling transmission)
- Called automatic reception
- Calling manual transmission
- Calling manual reception
- Called manual transmission
- Called manual reception
Communication mode
High-speed mode (Toshiba original procedure mode)
G3 mode
ECM (Error Correction Mode)
Circuit carrier link equalization function
Embedded
Output level
–16 dBm to –8 dBm (The setting can be changed by “1 dB”.)
Input level
–43 dBm to 0 dBm
(Level –55 dBm or lower cannot be detected)
Specifications of the communication mode
High-speed mode
(Toshiba original procedure mode)
G3 mode
ECM
Horizontal scanning den-
sity
8 dots/mm
300 dpi (Reception only)
16 dots/mm
Same as on the left
Same as on the left
Vertical scanning density
3.85 lines/mm
7.7 lines/mm
300 dpi (Reception only)
15.4 lines/mm
Same as on the left
Same as on the left
Encoding system
MH/MR/MMR/JBIG
MH/MR
MH/MR/MMR/JBIG
Minimum transmission
time for 1 line
2.5 ms
Same as on the left
Same as on the left
Transmission speed
(image signal) and modu-
lation method
14.4 k/12 k/9600
7200/4800/2400 bps
Conformance to V.17/V.29/V.27 ter
Same as on the left
33.6 k/31.2 k/28.8 k/
26.4 k/24 k/21.6 k/
19.2 k/16.8 k/14.4 k/
12 k/9600/7200/
4800/2400 bps
Control signal
300 bps
V.21
Same as on the left
2400/1200/600/
300 bps
V.34/V.8/V.21
Procedure to control the
transmission
Toshiba original procedure
T.30 conformance
Same as on the left