20
3. The base and handset cannot be connected.
Check whether the base
is able to set in the test
mode 1.
OK
NG
A
Check IC6 and its
peripheral circuit.
Check base RF unit.
NG
Check the TX POWER
and the TX FREQUENCY
on the base unit.
OK
NG
Check base RF unit.
Set the base in the test
mode 3, check whether
deviation of the TX data
is app. 8.5 kHz Dev.
OK
NG
Check whether there is a
250 Hz data waveform at
“MOD” of RF unit.
Check RT3, R51, R52,
R53, R48, R80, R81,
C59, C135 and C54.
NG
OK
Check base RF unit.
Set the base in the test
mode 8, 902.952467
MHz (250 Hz ±8 kHz
Dev.) 1mV output signal
from RF test point is
a p p l i e d . D o e s t h e
CHARGE LED light?
OK
NG
Check whether there is a
250 Hz data waveform at
RT2 AF test point.
Check IC2, Q1 and their
peripheral circuit.
NG
OK
Check whether there is a
250 Hz data waveform at
the Q2 collector.
Check RT2, Q2 and their
peripheral circuit.
NG
OK
Check whether there is a
250 Hz data waveform at
pin 44 of IC6.
Check IC3 and its
peripheral circuit.
NG
OK
Check IC6 and its
peripheral circuit.
Check whether the
handset is able to set in
the test mode 1.
OK
NG
Check IC603 and its
peripheral circuit.
Check the TX POWER
and the TX FREQUENCY
on the handset unit.
OK
NG
Check handset RF unit.
OK
Summary of Contents for FT-8989
Page 2: ...CORDLESS TELEPHONE SERVICE MANUAL FILE NO 2B0 9905 FT 8989 PUBLISHED IN JAPAN Sep 1999 ...
Page 11: ...9 BLOCK DIAGRAMS Base Unit Main ...
Page 12: ...10 Base Unit DSP ...
Page 13: ...11 Handset ...
Page 14: ...12 13 SCHEMATIC DIAGRAMS Base Unit Main ...
Page 15: ...14 15 Base Unit Key ...
Page 16: ...16 17 Handset ...
Page 34: ...35 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 35: ...36 Base Unit Key PCB ...
Page 36: ...37 Handset Main PCB ...
Page 37: ...38 39 WIRING DIAGRAMS Base Unit ...
Page 38: ...40 Handset ...
Page 66: ......