8
Receiver Section
Connections
Alignment Point Location on Handset Main PCB and Handset RF PCB
Preset
Place the Handset in RX SENS mode (step 4) in accordance with the procedure on page 4.
Alignment Procedure
step
1
2
3
Preset to
SG: 1mV
No modulation
SG: 1mV
1 kHz ±8kHz
deviation
SG: -6.0 dB
µµµµµ
V
No moduration
Remarks
Connect the RF Singal Generator to the RF test point on the handset MAIN
PCB. Make sure that the frequency is 926.997467 MHz.
Connect the DC Voltmeter to the Discriminator test point. Adjust L603 to
indicate DC 0.85 V.
Connect the RF Signal Generator to the RF test point on the handset MAIN
PCB. Make sure that the frequency is 926.997467 MHz.
Connect the AC Voltmeter across a 150-ohm dummy to the MIC Connector.
Adjust RT602 for a 35 mV reading on the AC Voltmeter.
Press the “5” key to enter the TEST Mode 5. Make sure that the frequency
of RF SG output is 926.997467 MHz. Adjust RT601 to turn to the point
where the Ringer just beeps.
Adjustment
L603
(Discriminator
Voltage)
RT602
(RX AF
Voltage)
RT601
(SQ Point)
AC Voltmeter
HANDSET Unit
AF
Terminal
Dummy Load
(150-ohm)
RF SG
DC 3.8V
J603
Battery
Connector
+
RF
Test Point
SP
Connector
DC Power Supply
DC Voltmeter
-
+
-
RF PCB
RF Test Point
L603
RT602
J603
Handset PCB
RT601
Discriminator Test Point
Summary of Contents for FT-8989
Page 2: ...CORDLESS TELEPHONE SERVICE MANUAL FILE NO 2B0 9905 FT 8989 PUBLISHED IN JAPAN Sep 1999 ...
Page 11: ...9 BLOCK DIAGRAMS Base Unit Main ...
Page 12: ...10 Base Unit DSP ...
Page 13: ...11 Handset ...
Page 14: ...12 13 SCHEMATIC DIAGRAMS Base Unit Main ...
Page 15: ...14 15 Base Unit Key ...
Page 16: ...16 17 Handset ...
Page 34: ...35 ELECTRICAL PARTS LOCATION Base Unit Main PCB ...
Page 35: ...36 Base Unit Key PCB ...
Page 36: ...37 Handset Main PCB ...
Page 37: ...38 39 WIRING DIAGRAMS Base Unit ...
Page 38: ...40 Handset ...
Page 66: ......