— 7 —
Handset Unit
Transmitter Section
Connection
Preset
Place the Handset in VCO/TX FREQ. ADJ mode in accordance with the procedure on page 4.
Alignment Procedure
Step
Adjustment
Remarks
1
VR502
(TX Power)
Connect the RF power Meter to the RF test point on the handset RF PCB.
Adjust VR502 for a
−
6 dBm reading on the Power Meter.
2
CT501
(TX Frequency)
Connect the Frequency Counter to the RF test point on the handset RF
PCB. Adjust CT 501 to make sure that the frequency is 903.079230 MHz.
3
VR601
(TX Modulation)
Press the “2” key to enter the TEST Mode 2. Connect the AF Generator to
the MIC Connector. Make sure that the output is 1 kHz 11.0 mV from the AF
Generator.
Connect the Deviation Meter to the RF test point on the handset RF PCB.
Adjust VR601 to indicate
±
8kHz Dev.
Alignment Point Location on Handset Main PCB and Handset RF PCB
Power
Meter
Frequency
Counter
Deviation
Meter
RF
Test Point
RF
Test Point
HANDSET RF PCB
RF
Test Point
MIC + Pin
1kHz 11.0mV
Battery
Terminals
HANDSET MAIN PCB
DC Power Supply
DC 3.8V
AF GEN.
CT501
VR502
VR601
J501
Handset Main PCB
RF PCB
MIC + Pin
MC601
RF TEST POINT
Battery Terminals
−
+
Summary of Contents for FT-8258
Page 1: ...SERVICE MANUAL PUBLISHED IN JAPAN Jun 1998 FILE NO 2B0 9801 FT 8258 CORDLESS TELEPHONE ...
Page 10: ...BLOCK DIAGRAMS Handset Main 9 ...
Page 11: ...Handset RF 10 ...
Page 12: ...Base RF 11 ...
Page 13: ...Base Main 12 13 ...
Page 14: ... 14 15 SCHEMATIC DIAGRAMS ...
Page 15: ... 16 17 Base RF ...
Page 16: ...Base Key 18 19 ...
Page 17: ... 20 21 Handset Main ...
Page 18: ... 22 23 Handset RF ...
Page 37: ...ELECTRICAL PARTS LOCATIONS Base Main 42 ...
Page 38: ...Base RF 43 ...
Page 39: ...Base Key 44 ...
Page 40: ...Handset Main 45 ...
Page 41: ...Handset RF 46 ...
Page 42: ...WIRING DIAGRAMS Base 47 ...
Page 43: ...Handset 48 ...
Page 75: ...MECHANICAL PARTS LIST ...