8
4. Base unit :
4.1 Test Equipment required and connection.
AC Power supply : 120V 50Hz
4.2. Preparation from alignment
Place the Base Board into test mode.
4.3. Alignment procedure :
Step
Preset
Adjustment
Remark
1
Base Board into test
mode
---
Connect the digital voltmeter to the point RX-
Loop -V. The reading should >0.25V DC and
<2.45V DC.
2
Base Board into test
mode
---
Connect the digital voltmeter to test point TX-
Loop -V. The reading should > 0.25V DC and <
2.45V DC.
3
Base Board into test
mode
BC151
Connect the digital voltmeter to test point Quad-
tune. Adjust for 2.2VDC at CH6.
4
Base Board into test
mode
BC92
Connect the Frequency counter to test point ANT.
Adjust for 903.8MHz at CH6.
5
Audio Gen : 1KHz,
-10dB (NO Load)
BR114
Connect the VTVM to test point PIN 3 of T1
Adjust for -10dB
6
Audio Gen : 1KHz,
-30dB (NO Load)
BR135
Connect the VTVM to test point TX Audio.
Adjust for -26dB.
Digital Voltmeter
RX -Loop-V TX-Loop-V RX-Audio
Quad-Tune /
Base unit
Pin3 of BT1/
Pin3 of BT1
(RF & Audio Board)
Tx Audio
TX Audio / REC +
9V DC IN ANT
Audio
Generator
VTVM
Adapter
Frequency
Counter
Summary of Contents for FT-3808BK
Page 8: ......
Page 9: ......
Page 11: ......
Page 12: ......
Page 15: ......
Page 16: ......
Page 32: ...ELECTRICAL PARTS LOCATION HANDSET PCB 30 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ...12 13 14 15 16 32 17 19 20 21 22 23 24 25 25 26 27 28 18 3 1 4 2 5 31 6 7 8 9 30 29 10 11 ...
Page 38: ...4 19 18 15 14 13 12 11 9 10 3 1 8 2 5 6 7 32 31 30 29 28 27 26 25 23 24 22 21 20 ...