background image

 

 FDX3543RP 

-25- 

 

DIMENSIONAL OUTLINE (2) 

(Interface Box) 

 

Unit: mm 

 

 
 

Summary of Contents for FDX3543RP

Page 1: ...ogy deliver higher sensitivity and better resolution Reflection coating on CsI Tl screen enables excellent Detective Quantum Efficiency DQE and low noise A high Modulation Transfer Function MTF FPD is the result of these outstanding technologies diagnostic images while delivering the benefits of lower radiation dose to the patient The FDX3543RP achieves a new level of functionality and reliability...

Page 2: ... Output DC15V 2 6A 30VA Overall Dimensions 115 185 85mm W H D V H Weight 1 kg approx Dimensional Outline Refer to pages 24 to 25 Environmental Under delivery and stock Temperature 15 55 Humidity 10 90 Non Condensing Pressure 50 106 kPa Under operating Temperature 10 35 Humidity 10 85 Non Condensing Pressure 70 106 kPa ACCESSORIES Cables AC Cable 1 8 m 1 GND Cable 3 m 1 CD CD Defect map SDK 1 pcs O...

Page 3: ...QE 0 Quantum Limited 70 A D Conversion 16 bit Ratings Energy Range 40 150 kVp Maximum Entrance Dose low Gain Linear Output Range 4 mR frame Interface Interface Box Sensor Unit UNIT Interface Connect to Interface Box Interface Box Unit Interface Connect to Sensor Unit Data Output 16 bit Digital Output Ethernet 1000BASE T Command Control Ethernet 1000BASE T X ray Synchronization Control External Pow...

Page 4: ...le DC15V is operating and supplying to Sensor Unit LED Display Mode Name Status POWER Turn on when power on ETHERNET Turn on when Connect Ethernet Detector PC User TFT Panel Gate Driver ROIC Unit Control Board Ethernet Interface Box DC15V Image Data Control X ray Control Unit User X ray Sync ...

Page 5: ...nal Name Type Ethernet Command Control PC D Sub Signal Control X ray Controller EXP_REQ INPUT OK OK EXP_OK OUTPUT N A OK EXP_REQ Command Response Digital Unit Interface Box Generator Panel Unit Sensor unit Power Unit PC Image Data Image Data Image Data DC Power DC Power DC Power X ray Sync ...

Page 6: ...etion of Refresh 2 Continues EXP_OK signal ON during Exposure ON period is defined by Image Acquisition mode table 3 Proceeds to Data Read after completion of Exposure 1 Single Exposure A EXP_REQ width Minimum 1ms B Refresh period For line drive 2984 Line scan 80 ms C EXP period Set value see the Image acquisition mode table 500 to 2000 ms by 500 ms step standard 500 ms D Read period For line driv...

Page 7: ...A B C C D C 2 Double Exposure A EXP_REQ width Minimum 1ms B Refresh period For line drive 2984 Line scan 80 ms C EXP period Set value see the Image Acquisition mode table 500 to 2000 ms by 500 ms step standard 500 ms D Read period For line drive 2984 Line Scan 240 ms EXP_REQ EXP_OK period Maximum 150 ms Double EXPOSURE cycle period Maximum 1700 ms case EXPOSURE 500 ms ...

Page 8: ...ce Description of the sequence 1 By receiving EXP_REQ request command during Refresh status proceeds to Exposure after completion of Refresh 2 Continues EXP_OK signal ON during Exposure ON period is defined by Image Acquisition mode table 3 Proceeds to Data Read after completion of Exposure 1 Single Exposure EXP_REQ EXP_OK period Maximum 150 ms EXP_REQ DATA STORAGE period Maximum 1700 ms case EXPO...

Page 9: ...Ref EXP_RE IN EXP_OK OUT EXPOSURE DATA_STRAGE Ready Exposure Read Exposure Read FPI ENABLED 1st 1st 2nd 2nd 2 Double Exposure EXP_REQ EXP_OK period Maximum 150 ms Double EXPOSURE cycle period Maximum 1700 ms case EXPOSURE 500 ms ...

Page 10: ...X ray exposure Period signal 4 0_EXP_OK OC Output Open Collector 5 NC Not connected 6 NC Not connected 7 EXP_REQ Input Image acquisition X ray exposure Request signal 8 0_TEXP_OK Output Image acquisition X ray exposure Period signal 9 0_EXP_OK OC Output Open Collector 1 Please put the protective resistance more than 1 4 kΩ in the series 2 Maximum sink current is 20 mA 2 External Interface EXT INF ...

Page 11: ... System Side FPI Side D Sub 9 Pin Connector 4 Output Circuit 4 1 5V CMOS Level Type 4 2 Open Collector Type Protective resistance more than 1 4kΩ must be inserted in series IP Address Select Switch Select IP address IP0 192 168 95 52 IP1 192 168 95 53 or User defined IP address Please use HUB when you connect two sensor units Dual use ...

Page 12: ...tronic equipment RF emissions CISPR 11 Class A The FPI is suitable for use in all establishments other than domestic and those directly connected to the public low voltage power supply network that supplies building used for domestic purposes Harmonic emissions IEC61000 3 2 Not applicable Voltage fluctuations flicker emissions IEC61000 3 3 Not applicable Note The FPI is not allowed to use the cabl...

Page 13: ...V differential mode 2kV common mode Mains power quality should be that of a typical hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC61000 4 11 5 UT 95 dip in UT for 5 sec 5 UT 95 dip in UT for 5 sec Mains power quality should be that of a typical hospital environment If the user of the FPI requires continued operation during power mains i...

Page 14: ... the compliance level in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol Note 1 At 80 MHz and 800 MHz the higher frequency range applies 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures object and people 3 This FPI can only allow to use the designated ca...

Page 15: ... at a maximum output power listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80MHz and 800MHz the separation distance for the higher frequency range applies 2 These guidelines may...

Page 16: ...tus refer to the dimensional outlines INSTALLING HOUSING IN APPARATUS 1 Surface of the base plate that locates FPI on the apparatus should be flat and smooth 2 It is necessary to clean both surface of FPI and the base plate of the apparatus before FPI is installed ...

Page 17: ...RIODIC CHECK ITEMS Check the following at a certain interval within one year 1 Appearance The sensor unit must be free from errors in appearance The outer mounting screws must be free from looseness and slip off The mounting screws to the equipment must be free from abnormalities such as looseness Each cable must be free from cracks and damages Each cable must be securely connected Any looseness i...

Page 18: ...and regulations 1 Electric Shock In operating do not touch the lead wires and connectors of the X Ray FLAT PANEL IMAGER FPI If necessary to touch lead wires and connectors please turn off the power supply and confirm no residual voltage exist before connecting disconnecting and handling them The housing of the FPI should always be connected to ground All ground terminals and ground wires shall be ...

Page 19: ...11 Load Please do not apply excessive load on the FPI Maximum load 150 kg In the whole 100 kg φ40 mm of the center 12 Unnecessary X ray Qualified Personnel The FPI is used combined with X ray tube assembly Only Qualified personnel for X ray handling procedures can use the FPI For set ups and services only knowleged enigineers or special service personnels are able to handle the FPI 13 X ray Shield...

Page 20: ...hange Do not use and set the FPI in an atmosphere of inflammable and or corrosion gasses Do not install FPI at around any electromagnetic wave noise sources 19 Condensation Do not let FPI in condensation situation at any time It may cause malfunctions of electronics circuit and deterioration of images 20 Dust and Particles Do not use FPI in the environment where dust and particles exist 21 Power S...

Page 21: ...isconnection the system should have a protective function which manages not allowing exposures 28 Fuses Fuses 250V T4AL are installed inside of Interface box Stop immediately using the FPI when fuse breaks 29 Defects It is natural due to characteristics of TFT that the FPI has defects Please calibrates corrects defects upon usage of FPI Defects can be corrected by using defect maps 30 Vibration No...

Page 22: ...FDX3543RP 22 CAUTION LABEL This label is a caution label to notify the user of the following point These contents are quite important for safety Attachment position Housing ...

Page 23: ...1 CE MARKING OF CONFORMITY 2 SERIAL NUMBER 3 MANUFACTURER 4 DATE OF MANUFACTURE 5 AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY 6 PROTECTIVE EARTH 7 WARNING CAUTION 8 HANDLE WITH CARE 9 LOAD WEIGHT RESTRICTION 10 TYPE B APPLIED PART ...

Page 24: ...FDX3543RP 24 DIMENSIONAL OUTLINE 1 Flat Panel Sensor Unit Unit mm ...

Page 25: ...FDX3543RP 25 DIMENSIONAL OUTLINE 2 Interface Box Unit mm ...

Page 26: ... REPRESENTATIVE TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF GERMANY PHONE 49 211 5296 107 FAX 49 211 5296 402 For Sales Technical Services please contact the following representative TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF GERMANY PHONE 49 211 5296 107 FAX 49 211 5296 402 TOSHIBA AMERICA ELECTRONIC COMPONENTS INC 2150 EAST LAKE COOK ROAD SUITE 310 BUFFAL...