      Specifications  

 

 Item 

Specification 

 Part number 

TOS-SN-1 

Indoors. Altitude of less than 1000m (3280ft) 

Service 

Environment 

Must not be exposed to direct sunlight, subject to corrosive 
and/or explosive gases, vapor, dust, chips, cutting oil, grinding 
agent, etc. 

Ambient 

Temperature 

From -10

0

C to+50

0

C (14

0

C to 104

0

C) 

Storage 

Temperature 

From -25

0

C

 to+65

0

C

 (-12

0

C

 to149

0

C

Relative humidity 

20% to 90% 

(no condensation allowed) 

 Vibration 

5.9m/s

2

 or less 

 Cool system 

Self-cooling 

 

Protection Functions 

 

If you receive an error code while operating the drive from the extended panel, refer to the table 
below for solutions to resolve the error. 

 

 Error Code 

Details 

Causes and Remedies  

г

AN.E 

г

ON.E 

CPU.E 

RAM error 
ROM error 
CPU error(watch 
dog) 

Reset the extended panel.  If the same indication 
appears again after resetting, ask the dealer to 
investigate the cause 

 

CON.E 

 

Communication 

error 

The error status will automatically be cancelled by 
recovery of normal communication status.  Check 
connection of the communication cable.  After checking 
connection of the communication cable, reset the 
extended panel. If the same indication appears again 
after resetting, ask the dealer to investigate the cause. 

 

 
 
 
 
 
 

Summary of Contents for Extended Panel TOS-SN-1

Page 1: ...play and adjustment of the inverter can be controlled remotely for up to 5 meters This operation manual gives explanations of how to connect and program the Extended Panel Please read the entire manual carefully before attempting to control your inverter via the Extended Panel In addition the manual can be used for future operator maintenance and inspection The Extended Panel is provided with a co...

Page 2: ...on connectors of the extended panel to the inverter CN1 which has the common serial option communication connector with the optional cable 3 Insure a secure connection is made between the inverter and the extended panel once the connection is made 4 Power on the inverter after connection has been made and the display should turn on Note Before removing the cable insure step 1 is confirmed Programm...

Page 3: ...shiba Adjustable Speed Drive Marketing Dept at 800 872 2192 Names and Functions The names and functions of main parts of the Extended Panel are shown in the following figure Even though the Extended panel is connected the inverter s panel remains available ...

Page 4: ... an opening for mounting the extended panel in front of the panel board Refer to Figure 1 Panel cut dimensions for proper dimensions and then set the extended panel in the opening with M3 screws nuts and spacers supplied as accessories Refer to Figure2 Mounting of extended panel for dimensions of extended panel Figure1 Panel cut dimensions Unit mm Dimensions Figure2 Dimensions of the extended pane...

Page 5: ...2 or less Cool system Self cooling Protection Functions If you receive an error code while operating the drive from the extended panel refer to the table below for solutions to resolve the error Error Code Details Causes and Remedies гAN E гON E CPU E RAM error ROM error CPU error watch dog Reset the extended panel If the same indication appears again after resetting ask the dealer to investigate ...

Page 6: ...could lead to electric shocks or fire Do not splash water over the product It could lead to electric shocks or fire Mandatory Power off the inverter before removing wires Turn off the power immediately if any abnormalities such as smokes smells or abnormal noise are found Neglecting any of these conditions could lead to a fire For repairs call your agency Transportation and installation Danger Pro...

Page 7: ...lation locations that may be subjected to rapid changes in ambient temperature and or humidity Route the control wires separate from the inverter input output power wiring When disconnecting connection cable make sure to hold its connector with care not to give unreasonable stress to the cable and the unit The optional cable connector has locking pawls to prevent disconnection at the inverter and ...

Reviews: