TROUBLESHOOTING
5 - 31
5
11)Skew (inclined image)
Fig. 5-11
Defective area
Step
Check items
Prescription
Drawers
1
Is the drawer properly installed?
Install the drawer properly.
2
Is there too much paper in the
drawer?
Reduce paper to 250 sheets or less.
3
Is the corner of the paper folded?
Change the direction of the paper
and set it again.
4
Are the side guides of the drawer
properly installed?
Adjust the position of the side guides.
Feed roller
5
Is the surface of the feed roller dirty?
Clean the feed roller surface with
alcohol, or replace the roller.
Rollers
6
Are the roller and shaft secured?
Check and tighten the E-rings, pins,
clips and setscrews.
Registration roller
7
Is the spring detached from the regis-
tration roller?
Attach the spring correctly. Clean the
roller if it is dirty.
Pre-registration guide
8
Is the pre-registration guide properly
installed?
Correct it.
CIS unit
9
Is the CIS unit slanted?
Replace the CIS case.
Feed system
10
Is the aligning amount proper?
Adjust the aligning amount.
Feeding direction