e-STUDIO163/166/203/206
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 8
(6)
After the adjustment for the code 411 is completed, apply the same adjustment value for the
code 410.
(Adjustment Mode)
#
(Key in the code [410])
#
[START]
#
(Key in the same value in the step 5 above)
#
Press [INTERRUPT] (Stored in memory).
Note:
Note:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[C] Reproduction ratio of secondary scanning direction (Fine adjustment of main motor rota-
tion speed (Copier/Printer))
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
#
(Adjustment mode)
(2)
Press [1]
#
[INTERRUPT]
#
[Drawer number] (Select from 0: bypass, 1: drawer or 2: PFU.)
#
[START]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from standard drawer of
the equipment.)
(3)
Check the grid pattern on the test chart printed out and measure the distance C from the 10th
line at the leading edge of the paper to the 30th line of the grid pattern.
*Normally, the 1st line of the grid pattern is not printed.
(4)
Check if the distance C is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance C again.
(Adjustment Mode)
#
(Key in code [421])
#
[START]
#
(Key in a value (acceptable values: 0 to 255))
#
[INTERRUPT] (Stored in memory)
#
“AJ” is displayed
#
Press [1]
#
[INTERRUPT]
#!
Press [Drawer number]
#
[START]
#
(A grid pattern is printed out.)
*The larger the adjustment value is, the longer the distance C becomes (approx. 0.125 mm/step).