Main code
Sub code
Content
43
09
Postcard size paper fusing control setup
46
01
Copy density adjustment
(Outline)
Used to adjust the copy density in each copy mode.(The copy density can be set by changing the set value of
ASIC GAMMA ADJUST register.)
Setting in each copy mode is performed at exposure level 3. When the copy density (exposure) is adjusted
arbitrarily, the max, and min. exposure levels are automatically calculated and set. (The change amounts
(gradient, change amount) at level 1 – 5 are predetermined.)
(Operation/Procedure)
1. When this simulation is executed, warming up and shading are performed and the current set value is
displayed in two digits.
2. Press the copy mode select key to select each setting mode and setting display.
∗
The copy mode setting is indicated with the following lamps as shown below.
3. Change the setting with the value up-down key and press the START key, and a copy will be made with the
entered set value.
4. Press the clear key to store the set value and exit the simulation.
The value displayed after execution of this simulation can be set in the range of 0 – 99 with 50 as the center
value.
When the text mode set value is Gat3, for example, the GAMMA ADJUST register value set at Exp1 is:
Text Exp1 = Gat3 – 50 – 24
When 40 is set to Gat3, Text Exp1 = 40 – 50 – 24 = –34
Then set the GAMMA ADJUST register set value to –34.
Perform the same procedure for each mode and each Exp.
∗
The above table may subject to change.
∗
For the gradient, there is a similar table, though not specified here. The value set with SIM 46, however, is
not reflected.
∗
The AE mode Exp selection is not specified, but corresponds to the grades for AE exposure selection in the
former models.
19
γ
table setup
When this simulation is executed, the currently set gamma table code number is displayed. Enter the code
number corresponding to your desired gamma table and press the PRINT switch, and the setup will be changed.
Code number
Setup
0
Cancel (Default)
1
Setup
Copy mode
Display lamp
AE mode
AE mode lamp
TEXT mode
TEXT mode lamp
PHOTO mode
PHOTO mode lamp
TS mode (TEXT)
TEXT mode lamp & PHOTO mode lamp
TS mode (AE)
AE mode lamp & PHOTO mode lamp
Relationship between the displayed values and the GAMMA ADJUST register
Exp1
Exp2
Exp3
Exp4
Exp5
AE
–24
–12
0
+12
+24
TEXT
–24
–12
0
+12
+24
PHOTO
–24
–12
0
+12
+24
T/S
–24
–12
0
+12
+24
Code number
γ
table
1
Japan
2
EX Japan
DP1200/1500
10 – 9
Summary of Contents for DP1200
Page 1: ...DIGITAL PLAIN PAPER COPIER DP1200 1500 File No 31100024 ...
Page 2: ...Copyright 2001 TOSHIBA TEC CORPORATION ...
Page 103: ...GDI PWB DP1200 Only DP1200 1500 14 15 ...
Page 104: ...GDI MEMORY PWB 4MB DP1200 Only DP1200 1500 14 16 ...
Page 110: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...