74 / 80
Copyright © 2014 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htm
D4235067D
● Registers
Register
Visibility
Access
Description
UserSetSelector
Beginner
R/W
Selects a bank of user setting.
UserSetLoad
Beginner
W
Executes load of the user setting.
UserSetSave
Beginner
W
Executes to save the user setting.
UserSetDefaultSelector
Beginner
R/W
Selects a bank of user setting when camera powers up.
● Setting
- Select a bank of the user setting
Set the following value to “UserSetSelector” register. The setting value is Enumeration type.
Select the bank of user setting for
“UserSetLoad” and “UserSetSave”.
Value
Description
Save
Load
Default (*)
Memory bank to read initial factory setting data.
×
○
UserSet1
Memory bank 1 for user setting.
○
○
UserSet2
Memory bank 2 for user setting.
○
○
UserSet3
Memory bank 3 for user setting.
○
○
* initial factory setting
“Default” bank is only used for loading data. If you want to restore a camera setting to the initial factory
setting, please load
“Default” bank.
- Load/Save a user setting
When execute “UserSetLoad”, the camera loads the user setting of bank that is selected in
“UserSetSelector” register and applies them.
When execute “UserSetSave”, the camera saves a user setting that was applied to the bank that is
selected in “UserSetSelector” register.
- Load the user setting at the time of start-up
Set the following value to “UserSetDefaultSelector” register. The setting value is Enumeration type.
When select
“UserSetDefaultSelector” register and save it, the camera loads the user setting of bank that
is selected in “UserSetDefaultSelector” register and applies them at the time of next start-up.
● Note
Changing “UserSetLoad” register value is invalid during image stream data output.