49 / 80
Copyright © 2014 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htm
D4235067D
● Setting
- Selects trigger type
Set
the following value to “TriggerSelector” register. Setting value is Enumeration type.
Value
Operation Mode
FrameStart(*)
Normal Trigger mode
FrameBurstStart
FrameBurst mode
* initial factory setting
- Selects trigger mode
Set
the following value to “TriggerMode” register. Setting value is Enumeration type.
Value
Operation Mode
Off (*)
Normal Shutter Mode
On
Random Trigger Shutter mode
* initial factory setting
- Selects trigger source
Set the following value
to “TriggerSource” register. Setting value is Enumeration type.
Value
Trigger source
Line0 (*)
Hardware trigger
Software
Software trigger
* initial factory setting
- Grabs image stream by software trigger
When executes
“TriggerSoftware” register command, software trigger command is generated. And the