Charging time  

To charge an empty battery pack:  

 

Battery pack 

Charging time 

B-EP802-BT-QM-R 

about 3 hours  
(Until min. of 85% of the nominal capacity is charged.) 

B-EP804-BT-QM-R 

about 3 hours  
(Until min. of 85% of the nominal capacity is charged.) 

 

• Charging  time  may  differ  depending  on  the  condition  of  the  battery  pack  or  the 

operating temperature.  

• After the CHARGE lamp turns from red to green, the battery charger may continue 

to charge the battery pack for up to one more hour until the full charge level (95% 

or more).     

 
 

NOTES: 

 

1. Battery packs should be charged on condition that both ambient temperature and 

battery temperature fall within a range of 0 °C to 40°C.  

2. The battery charger will get warmer during charging (room tempe about 

30°C). This is not abnormal.  

3. If the over discharge protector has been operated on a battery pack, the 

CHARGE lamp may not light for a while. Leave the battery charger and the battery 
pack alone for a few minutes.  Stop using the battery pack if the CHARGE lamp 
does not light at all as the battery pack may be faulty. 

4. After the charging is completed, do not leave the battery pack in the charger too 

long.  The battery pack gradually discharges. 

5. The  battery  pack  can  be  removed  from  the  battery  charger  while  charging  is  in 

progress.  However, the battery lasting time depends on the charging time.

 

6. Periodically clean the charger terminals with a soft dry cloth.  

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for B-EP800-CHG6-QM-R

Page 1: ...TOSHIBA 6 Slot Battery Charger B EP800 CHG6 QM R Owner s Manual 00TSCC0214306 ...

Page 2: ...ure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance NOTE No user serviceable parts inside Refer servicing to qualified service personnel This product is designed for commercial usage and is not con...

Page 3: ...ion dangereuse non isolée d une amplitude suffisante pour constituer un risque potentiel de choc électrique aux personnes Ce symbole est prévu pour alerter l utilisateur de la presence dans le manuel d instructions importantes pour l utilisation ou l entretien NOTE Ne contient aucun élément interne réparable par l utilisateur Adressez vous à du personnel de maintenance qualifié Copyright 2011 by T...

Page 4: ...Zigarettenanzünder B EP802 DC12 QM R DC Adapter B EP800 DC48 QM R ATENCIÓN 1 Utilice baterías diseñadas y fabricadas por Toshiba Tec específicamente para este modelo Existe riesgo de explosión si se usa un tipo de batería incorrecto Deshágase de las baterías usadas según las instrucciones B EP802 BT QM R B EP804 BT QM R 2 Cuando conecte un alimentador externo a la impresora como por ejemplo un ada...

Page 5: ...QM R DC 어댑터 B EP800 DC48 QM R 注意 注意 注意 注意 1 套装充電池只適用与本機専用品 更換不適當形式的電池時 持有爆發的危険性 使用過後的電池 請按照説明書處理 B EP802 BT QM R B EP804 BT QM R 2 聯接本機的AC電源供應器等外部電源時 只適用与本機的専用品 請勿聯接本機専用品之外任何産品 AC 電源供應器 B EP800 AC QM R Model FSP065 RAB K34001 點烟機電源供應器 B EP802 DC12 QM R DC 電源供應器 B EP800 DC48 QM R ATENÇÃO 1 Utilize as baterias desenhadas e fabricadas pela Toshiba Tec especificamente para este modelo Existe risco de ...

Page 6: ...eurs intégrés peuvent être laissés en place ils seront récupérés par le centre de recyclage La barre noire indique que ce produit a été mis sur le marché après le 13 Août 2005 En vous assurant que ce produit est correctement mis au rebut vous participerez à prévenir les éventuelles conséquences néfastes sur l environnement et la santé publique qui pourraient autrement être causés par une gestion i...

Page 7: ...ylizacja urządzeń na podstawie dyrektywy Unii Europejskiej 2002 96 EC Dyrektywa dotycząca odpadów elektrycznych i elektronicznych WEEE Użycie symbolu oznacza że urządzenie nie może być traktowane jako niesegregowane odpady i musi być zebrane oddzielnie Zintegrowane baterie i akumulatory mogą być utylizowane razem z urządzeniem Zostaną one posegregowane w centrach utylizacji Czarny prostokąt oznacz...

Page 8: ...sted and found to comply with the limits for a Class A digital device pursuant to Part15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may ca...

Page 9: ... intérieur uniquement 5 N utilisez pas un spray nettoyant contenant du gaz inflammable pour nettoyer ce produit car cela pourrait provoquer un incendie CAUTION For customers in U S A and Canada 1 To prevent electric shock match wide blade of plug to wide slot fully insert 2 To reduce the risk of hazards use only CSA UL Certified power cord set Cord is TypeSPT 2 or heavier minimum NO 18 AWG copper ...

Page 10: ...ting plate If it does a short may occur and the unit may be damaged Always keep the metal contacts clean Do not disassemble or convert the unit Do not apply mechanical shock or drop the unit The unit may become warm whilst in use this is perfectly normal Keep the unit away from AM receivers because it will disturb AM reception Do not place the unit in a location where it is Temperatures out of the...

Page 11: ...WARNING 1 The B EP800 CHG6 QM R battery charger is exclusively used for the B EP802 BT QM R B 804 BT QM R lithium ion battery pack DO NOT charge any other battery packs or explosion combustion or overheating may result 2 If the battery charger gives out smoke a bad smell or extraordinary heat unplug the power cord from the outlet immediately Failure to do this may cause fire or electric shock AVER...

Page 12: ...te size of the battery pack according to the partition s orientation Failure to do this may damage the battery pack or affect charging operation The CHARGE lamp indicates a charging status CHARGE lamp State OFF Unconnected Red Charged Green Completed Blinking red Abnormal state 6 After charging is completed remove the battery pack from the battery charger 7 Disconnect the power cord from the AC ou...

Page 13: ...e and battery temperature fall within a range of 0 C to 40 C 2 The battery charger will get warmer during charging room temperature about 30 C This is not abnormal 3 If the over discharge protector has been operated on a battery pack the CHARGE lamp may not light for a while Leave the battery charger and the battery pack alone for a few minutes Stop using the battery pack if the CHARGE lamp does n...

Page 14: ...tely after loading a battery Leave the battery charger and the battery pack alone for a few minutes If the CHARGE lamp does not light after all stop using the battery pack as the battery pack may be faulty The partition is not fitted Fit the partition in the correct orientation The CHARGE lamp blinks in red A battery pack failure is detected It could be the end of battery life Replace the battery ...

Page 15: ...ly The battery pack model is automatically sensed Operating temperature 0 C to 40 C 32 F to 104 F Operating humidity 20 to 80 no condensation Storage temperature 20 C to 60 C 4 F to 140 F Storage humidity 10 to 85 no condensation Dimensions 148 x 77 x 213 mm w h d 5 83 x 3 03 x 8 39 excluding the projecting parts 72 x 40 x 171 mm w h d 2 83 x 1 57 x 6 73 excluding the projecting parts Weight Appro...

Page 16: ...NEMKO Europe HAR France UTE Spain AEE China CCC Power Cord Instruction 1 For use with 100 125 Vac mains power supply please select a power cord rated Min 125V 10A 2 For use with 200 240 Vac mains power supply please select a power cord rated Min 250V 3 Please select a power cord with the length of 2m or less Country Region North America Europe United Kingdom Australia China Power Cord Rated Min Ty...

Reviews: