65/5560 ADJUSTMENT
MAY.1997 © TOSHIBA CORP.
2-20
At the initial machine setup or when the developer material is replaced,the auto-toner sensor needs
to be adjusted.
<Key Operation>
0 5
POWER
0
: Enter code
(operation state of
developer, drum, etc.)
<Display, Supplementary Explanation>
INT
0 9
(developer, drum,
etc. stop)
ZOOM
Adjust so that "XXX" on the display panel is within the
permissible range only when outside of range 245 to 255.
XXX
ZZZ
ZOOM UP key
Increases
Increases
ZOOM DOWN key
Decreases
Decreases
* Auto-toner sensor output range: 2.45 to 2.55V
After about two minutes, "XXX" and "ZZZ" automatically
start to change. Then the following is displayed:
:
Cancel adjustment
mode.
2.6 Auto-Toner Sensor Adjustment
↓
↓
↓
↓
↓
ò
XXX
Z Z Z
WAIT
100%
ò
Auto-toner sensor output voltage: X.XXV
↓
←
XXX
Z Z Z
ADJUST MODE
100%
Stops changing
↓
↓
TEST MODE A
100%
A
TEST MODE A
100%
A
Numerical value corresponding
to auto-toner adjusting value
Return
Skip
76/7560 S/H