background image

ECO OPERATION

9

COMFORT SLEEP OPERATION

12

To automatically control room temperature to save energy (except in DRY 
and FAN ONLY mode)

Press 

: Start and stop the operation.

Note :

  Cooling operation; the set temperture will increase automatically

1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperture will decrease.

Fireplace Operation (

)

Keep indoor unit’s fan blowing continuously during thermo off, to circulate heat 
from other sources over the room. There are three setting parameters: Default 
setting > Fireplace 1 > Fireplace 2

Fireplace 1:

During thermo off period, the indoor unit’s fan will continue to run by the same 
speed, previously selected by end-user.

Fireplace 2:

During thermo off period, the indoor unit’s fan will continue to run at super-low 
speed, programmed from factory.

8°C Heating Operation (8°C)

Heat mode operation for keep room temperature (5-13°C) with less of energy 
usage.

Fireplace and 8°C Heating Operation

8°C

FIREPLACE 1

FIREPLACE 2

Normal 

operation

Note

:  

 

While Fireplace operation on heating mode, indoor unit fan always runs 
and cold air breezing might be occurred.

 

Fireplace and 8°C will operate in Heating mode only.

For comfortable sleep, automatically control air 

fl

 ow and automatically turn 

OFF (Except in DRY mode).

1.  Press 

 : Select 1, 3, 5 or 9 hrs for OFF timer operation.

2.  Press 

 to cancel the comfort sleep operation.

Note

:   The cooling operation, the set temperature will increase automatically 

1 degree/hour for 2 hours (maximum 2 degrees increase). For heating 
operation, the set temperature will decrease.

HADA CARE FLOW
Air 

fl

 ow upward to the ceiling, provide Indirect air 

fl

 ow to body and 

homogenize room temperature.

AIR FLOW

Comfortable air 

fl

 ow can select from this feature.

HADA CARE FLOW and AIR FLOW operation

  

Press 

  For start operation as sequence below

Cancel

Air Flow

Wide center

Spot left

Wide right

Spot right

Wide left

Spot center

HADA CARE FLOW

Note

:

 

During HADA CARE FLOW mode, FIX and SWING button cannot active

POWER-SELECTION AND SILENT 
OPERATION (OUTDOOR UNIT)

14

Power-Selection (

)

This function is used when the circuit breaker is shared with other electrical 
appliances. It limits the maximum current and power consumption to 100%, 
75%, or 50% and can be implemented by POWER-SELECTION. The lower 
percentage, the higher saving and also longer compressor lifetime.

Note

:  

 

When the level is selected, POWER-SEL level 

fl

 ashes on remote LCD 

display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also 

fl

 ashes for 2 

seconds.

 

Due to the reason that POWER-SELECTION function limits the 
maximum current, inadequate cooling or heating capacity may occur.

Silent Operation (

)

Keep outdoor unit operating silently to ensure either yourself or neighborhood 
will have a tight sleep in nighttime. By this feature, the heating capacity will 
be optimized to deliver such silent experience. The silent operation can be 
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2

Silent 1:

Though operating silently, the Heating (or Cooling) capacity is still prioritized 
to ensure having suf

fi

 cient comfort inside the room.

This setting is a perfect balance between the Heating (or Cooling) capacity 
and the Sound level of outdoor unit.

Silent 2:

Compromising the Heating (or Cooling) capacity to the Sound level in any 
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor 
unit by 4 dB(A).

Note

:  

 

While activating of Silent operation, inadequate heating (or cooling) 
capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit)

[100%]

[75%]

[50%]

SILENT#2

SILENT#1

HADA CARE FLOW AND AIR FLOW 
OPERATION

13

FIREPLACE AND 8°C HEATING 
OPERATION

10

11

PLASMA ION

Capture ef

fi

 ciency of 

fl

 oating impurities in the air is accelerated by plasma ion 

contaminates such as bacteria, odor, smoke, dust and virus are caught and 
deactivated by Plasma lon.

1. When stopping operation.

 

After stopping, automatic cleaning starts 
(TIMER lamp turns on).
*  When operating time is 10 minutes 

or less, cleaning function does not operate.

2. When using together with the air conditioning

Air volume and direction setting of air conditioner have priority.

Operation

 

Operate Plasma lon while air conditioning.

Press the 

PURE

 button.

Stop

 

Stop both Plasma lon and air conditioning.

Press the 

 button.

 

Stop only Plasma lon.

Press the 

PURE

 button.

Note :

  Plasma lon operation does not remove harmful substances from 

cigarette smoke (carbon monoxide etc.). Open a window occasionally 
for ventilation.

PURE

or

Summary of Contents for 24E2AVSG-A

Page 1: ...1120650280 OWNER S MANUAL R32 AIR CONDITIONER SPLIT TYPE For general public use Indoor unit Outdoor unit RAS 18 22 24E2AVSG A RAS 18 22 24E2KVSG A ...

Page 2: ...m without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater In order to avoid fire explosion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the ...

Page 3: ...mal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium fin because it may cause an injury Before cleaning the unit turn off the main switch or the circuit breaker When the unit won t be used for a long time turn off the main switch or the circuit breaker It is recommended that maintenance be performed by a specialist when the...

Page 4: ...lect Dry 2 Press Set the desired temperature Min 17 C Max 30 C Note DRY mode fan speed is set to Auto only Hi POWER OPERATION 8 To automatically control room temperature and airflow for faster cooling or heating operation except in DRY and FAN ONLY mode Press L 32 5 Start and stop the operation 1 Press Move the louver in the desired vertical direction 2 Press FIX Move the louver in the desired hor...

Page 5: ...power consumption to 100 75 or 50 and can be implemented by POWER SELECTION The lower percentage the higher saving and also longer compressor lifetime Note When the level is selected POWER SEL level flashes on remote LCD display for 3 seconds In case of 75 and 50 level number 75 or 50 also flashes for 2 seconds Due to the reason that POWER SELECTION function limits the maximum current inadequate c...

Page 6: ...he button is pressed once during Cool or Dry mode the fan will continue to run for other 30 minutes then it will turn off automatically This will reduce the moisture in the indoor unit 2 To stop the unit immediately press the more 2 times within 30 seconds TEMPORARY OPERATION In case of the misplaced or discharged remote control Pressing the RESET button the unit can start or stop without using th...

Page 7: ...ss to enter WEEKLY TIMER setting 2 Press to select desired day in sequence The sequence of day symbol appears on the LCD SU t MO t TU t WE t TH t FR t SA WEEKLY SUMO TUWETHFRSA All day 3 Press to select the program number The program 1 is ready for setting while is pressed PG 1 appears on the LCD Press to change the program number in the sequence program 1 to program 4 PG 1 PG 2 PG 3 PG 4 4 Press ...

Page 8: ...ws the next program The program after reactivation is related to the clock time To delete programs The individual program 1 Press The day of the week and the program number is displayed Select the day to delete the program 2 Press to select the program number to be deleted 3 Press ON or OFF timer will be cleared and the LCD will blink 4 Press to delete the program Press while the LCD is blinking T...

Page 9: ...MEMO ...

Page 10: ...MEMO ...

Page 11: ......

Page 12: ...1120650280 ...

Reviews: