ECO OPERATION
9
COMFORT SLEEP OPERATION
12
To automatically control room temperature to save energy (except in DRY
and FAN ONLY mode)
Press
: Start and stop the operation.
Note :
Cooling operation; the set temperture will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperture will decrease.
Fireplace Operation (
)
Keep indoor unit’s fan blowing continuously during thermo off, to circulate heat
from other sources over the room. There are three setting parameters: Default
setting > Fireplace 1 > Fireplace 2
Fireplace 1:
During thermo off period, the indoor unit’s fan will continue to run by the same
speed, previously selected by end-user.
Fireplace 2:
During thermo off period, the indoor unit’s fan will continue to run at super-low
speed, programmed from factory.
8°C Heating Operation (8°C)
Heat mode operation for keep room temperature (5-13°C) with less of energy
usage.
Fireplace and 8°C Heating Operation
8°C
FIREPLACE 1
FIREPLACE 2
Normal
operation
Note
:
●
While Fireplace operation on heating mode, indoor unit fan always runs
and cold air breezing might be occurred.
●
Fireplace and 8°C will operate in Heating mode only.
For comfortable sleep, automatically control air
fl
ow and automatically turn
OFF (Except in DRY mode).
1. Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
2. Press
to cancel the comfort sleep operation.
Note
: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
HADA CARE FLOW
Air
fl
ow upward to the ceiling, provide Indirect air
fl
ow to body and
homogenize room temperature.
AIR FLOW
Comfortable air
fl
ow can select from this feature.
HADA CARE FLOW and AIR FLOW operation
Press
For start operation as sequence below
Cancel
Air Flow
Wide center
Spot left
Wide right
Spot right
Wide left
Spot center
HADA CARE FLOW
Note
:
●
During HADA CARE FLOW mode, FIX and SWING button cannot active
POWER-SELECTION AND SILENT
OPERATION (OUTDOOR UNIT)
14
Power-Selection (
)
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%,
75%, or 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
Note
:
●
When the level is selected, POWER-SEL level
fl
ashes on remote LCD
display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also
fl
ashes for 2
seconds.
●
Due to the reason that POWER-SELECTION function limits the
maximum current, inadequate cooling or heating capacity may occur.
Silent Operation (
)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized
to ensure having suf
fi
cient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor
unit by 4 dB(A).
Note
:
●
While activating of Silent operation, inadequate heating (or cooling)
capacity may occur.
Power-Selection and Silent Operation (Outdoor Unit)
[100%]
[75%]
[50%]
SILENT#2
SILENT#1
HADA CARE FLOW AND AIR FLOW
OPERATION
13
FIREPLACE AND 8°C HEATING
OPERATION
10
11
PLASMA ION
Capture ef
fi
ciency of
fl
oating impurities in the air is accelerated by plasma ion
contaminates such as bacteria, odor, smoke, dust and virus are caught and
deactivated by Plasma lon.
1. When stopping operation.
●
After stopping, automatic cleaning starts
(TIMER lamp turns on).
* When operating time is 10 minutes
or less, cleaning function does not operate.
2. When using together with the air conditioning
Air volume and direction setting of air conditioner have priority.
Operation
●
Operate Plasma lon while air conditioning.
Press the
PURE
button.
Stop
●
Stop both Plasma lon and air conditioning.
Press the
button.
●
Stop only Plasma lon.
Press the
PURE
button.
Note :
Plasma lon operation does not remove harmful substances from
cigarette smoke (carbon monoxide etc.). Open a window occasionally
for ventilation.
PURE
or