Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
●
Clean the indoor unit and the remote control with a wet cloth when
needed.
●
No benzine, thinner, polishing powder or chemically-treated duster.
Air
fi
lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air
fi
lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air
fi
lters and close the air inlet grille.
MAINTENANCE
23
The unit does not operate.
Cooling or Heating is abnormally low.
●
The power main switch is
turned off.
●
The circuit breaker is activated
to cut off the power supply.
●
Stoppage of electric current
●
ON timer is set.
●
The
fi
lters are blocked with dust.
●
The temperature has been set
improperly.
●
The windows or doors are opened.
●
The air inlet or outlet of the outdoor
unit is blocked.
●
The fan speed is too low.
●
The operation mode is FAN or DRY.
●
POWER SELECTION function is
set 75% or 50% (
This function is
depend on remote controller
).
TROUBLESHOOTING (CHECK POINT)
24
How to set WEEKLY TIMER
1. Press
to enter WEEKLY TIMER setting.
2. Press
to select desired day in sequence.
The sequence of day symbol appears on the LCD.
SU
t
MO
t
TU
t
WE
t
TH
t
FR
t
SA
WEEKLY SUMO
TUWETHFRSA
(All day)
3. Press
to select the program number.
●
The program 1 is ready for setting while
is
pressed PG-1 appears on the LCD.
●
Press
to change the program number in
the sequence program 1 to program 4.
PG-1
PG- 2
PG- 3
PG- 4
4. Press
or
to select the desired time.
●
The time can be set between 0:00 and 23:50 in
10 minute intervals.
●
Press and hold the button to change setting time
for 1 hr.
●
Only one of ON or OFF timer can be set on each
program.
ON timer display
OFF timer display*
* OFF timer is used to stop the air conditioner only.
The display does not show Operation mode,
Temperature, Fan speed and others.
5. Press
to select desired operation.
6. Press
or
to select desired temperature.
●
The temperature can be set between 17°C and
30°C.
7. Press
to select the desired fan speed.
8. Add operations, if required.
●
Press
to use 8°C operation.
(Notes: Fireplace cannot select and memorize in
weekly function)
●
Press
to use ECO operation.
●
Press
to use Hi POWER operation.
●
Press
to use Silent operation.
WEEKLY TIMER OPERATION
25
Blink