– 2
4
–
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
2
3
4
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
ICF-340-30-2
Β
( — )
( — )
MP24Z3T
DC340V, 30W
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
9
10
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Heat exchanger temp. sensor (TE sensor)
Terminal block (
5
P)
Compressor
Coil for PMV
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA130A1F-27F
DA150A1F-20F
CAM-MD12T
CTH-2
Rating
L = 10mH, 16A
DC140V, 43W
10k
Ω
(25°C)
62k
Ω
(20°C)
10k
Ω
(25°C)
10k
Ω
(25°C)
20A, AC250V
3-phases 4-poles 1100W
DC12V
AC220–240V
FILE NO. SVM-10050
Fan motor (for indoor)
Parts name
Type
Specifications
Coil for 4-way valve
STF
22SAV-E
2, 22SAV2-E,
18SAV-E
2, 18SAV2-E,
18SAV2-A
22SAV
2
-
A