Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
• Use Ø8 mm or Ø10 mm anchor bolts and nuts.
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
For the rear left, bottom left and left piping
Cut out a piece of SPACER from indoor
unit packaging box, roll it and insert
between the indoor unit and wall to tilt
the indoor unit for better operation.
Wall
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Right
Rear
right
Rear
left
Left
Bottom
right
Bottom left
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
Cut the piping
hole sloped
slightly.
The flare connection should be installed
outdoors.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
Hook
Installation
plate
Shield pipe
1
Hook
65 mm or more
300 mm or more
300 mm or more
Filter
Batteries
(Attach to the front panel.)
Air filter
5
3
Flat head
wood screw
Wireless remote control
Remote control holder
7
2
4
Vinyl tape
Apply after carrying
out a drainage test.
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
Saddle
Extension drain hose
(Not available, provided
by installer)
600 mm or more
100 mm or more
100 mm or more
600 mm or more
600 mm or more
Air inlet
Air outlet
Optional Installation Parts
Part
code
Parts name
Q’ty
A
Refrigerant piping
Liquid side : Ø6.35 mm
Gas side : Ø9.52 mm
One
each
B
Pipe insulating material
(polyethylene foam, 6 mm thick)
1
C
Putty, PVC tapes
One
each
Drain outlet