11
ELECTRICAL WORKS
ELECTRICAL WORKS
Model
RAS-10J2KCVRG-T
RAS-13J2KCVRG-T
Power source
50Hz, 220V Single phase
Maximum running current
5.30A
6.85A
Circuit breaker rating
7.0A
9.0A
Power supply cable
H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
Connecting cable
Wiring Connection
Wiring of the connecting cable can be carried out without removing the
front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local cords) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 20 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it tightly
with screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
Indoor unit
Front panel
Air inlet grille
Screw
Screws
Terminal cover
Cord clamp
• When attaching the air inlet grille, the contrary of the removed operation is
performed.
How to install the air inlet grille on the indoor
unit
1. Remove the valve cover, the electric parts cover and the cord clamp from
the outdoor unit.
2. Connect the connecting cable to the terminal as identified by the
matching numbers on the terminal block of indoor and outdoor unit.
3. Insert the power cord and the connecting cable carefully into the terminal
block and secure it tightly with screws.
4. Use vinyl tape, etc. to insulate the cords which are not going to be used.
Locate them so that they do not touch any electrical or metal parts.
5. Secure the power cord and the connecting cable with the cord clamp.
6. Attach the electric parts cover and the valve cover on the outdoor unit.
Outdoor unit
Terminals block
Valve cover
1122350101-00_S01_182x257_32p_S_p70_181210.indd 11
26/1/2562 9:50:12