background image

40

41

Deutsch

English

Deutsch

English

1. Important safety and operating advice

DANGER

This symbol warns about risks of injury to yourself and others.

The product is designed to operate safely and reliably as long as it is used according to the 
operating manual. Please read this manual carefully before starting the battery. Non-com-
pliance with these instructions may cause property damage and/or bodily injury.  Torqeedo 
assumes no liability for damage caused by any activities contrary to the present operating 
manual.

To ensure safe operation of the battery:
•  Before every use, check the condition and functionality of the battery.
•  Only let adults run the battery who have been instructed on operation of the latter.
•  In case you don‘t use the battery with Torqeedo products and cable sets, please use 

suitable cable cross-sections for connecting the equipment (risk of fire).

•  Torqeedo cable sets always contain a main switch and suitable fuse. In case you should 

not use Torqeedo cable sets for electrical installation, always use a main battery switch 
approved for switching current and equipped with a fuse.

•  Voltages of up to 60 V may occur on contacts. Avoid contact with hands.
•  Even though Power 26-104 meets requirements of IP 67 protection class (protection 

against temporary immersion in water), it should not be exposed to long-term moi-
sture or placed in water in order to prevent risks of short-circuits in case of untight 
housings.

•  Secure Power 26-104 to prevent slipping and tilting. Only mount battery in a horizontal 

position, grips directed upwards.

•  Before the first use, charge the battery completely in order to calibrate the charge level 

readout.

•  The Torqeedo Power 26-104 can only be stacked for storage, it must not be stacked in 

operation.

•  When connecting more than one Power 26-104 battery to form a battery bank:

-  Batteries connected in series and in parallel must imperatively have the same state of 

charge. Thus only use same type of batteries for interconnection (same capacity, age, 
manufacturer and state of charge) and fully charge every battery separately with the 
charger before their interconnection. Differences in state of charge may induce extre-
mely high compensating currents overcharging cables and connectors or the battery 
itself. In extreme cases even fire or injury may be the result.

-  Incorrect interconnection of lithium batteries induces much higher short circuit cur-

rents than it is the case for lead batteries. Although Power 26-104 is protected against 
high compensating currents, we urge you to have interconnection of multiple Power 
26-104 batteries performed by specialised staff.

•  Never open battery housing. Protect battery against mechanical damage. In case  

battery housing has been damaged:
-  Neither use nor charge battery any more. There is a risk of fire.
-  In case any electrolytes should leak from damaged battery, avoid skin contact and 

direct inhalation of gases. In case your skin or eyes have come into direct contact with 
electrolytes leaking from the battery, rinse them thoroughly with clear water. Immedi-
ately contact a doctor. Contact Torqeedo service center for information upon disposal 
of the damaged battery.

•  Absolutely avoid wearing metallic jewelry when working on or staying beside bat-

teries. Do not place metallic tools on the batteries either as this may induce court-
circuits. Only use insulated tools.

•  Only charge battery on a non-flammable surface under supervision of an adult.
•  Only charge battery at ambient temperatures of between 0°C and 45°C / 32°F and 

113°F.

•  Keep battery away from fire.
•  Please note that since 2009, lithium batteries with a capacity of >100 Wh may no 

longer be carried as luggage in passenger planes. This battery exceeds said threshold 
and may therefore neither be transported as hand luggage nor in the hold of passen-
ger planes.

•  Battery is declared as hazardous good according to UN Class 9. In case of transpor-

tation of the product by transportation companies, original packaging must be used. 
Private transport is not affected by this ruling. In case of private transport, make sure 
that battery housing is not damaged. 

•  For the event that shipping should become necessary at a later moment, keeping of 

original packing is recommended. 

•  Beside these selected warnings, please observe complete operating manual.
•  The battery may be transported only while disconnected from the power supply. The 

battery can either be switched off manually for that purpose or will switch off automa-
tically within 48 hours after use.

•  Make sure to check the charge status of the battery regularly during long-term sto-

rage. Recharge if necessary.

Summary of Contents for Power 26-104

Page 1: ...Power 26 104 Bedienungsanleitung Deutsch Operating Manual English Deutsch English...

Page 2: ...blembeschreibung inklusive Fehlermeldung in welcher Situation trat der Fehler auf etc Vorgangsnummer bei Einsendung an das Torqeedo Service Center in Gilching zwingend erforderlich die Sendung kann an...

Page 3: ...34 35 Deutsch English Deutsch English...

Page 4: ...ller display Torqeedo s Power 26 104 battery is by far the most complete and customer friendly battery management system available on the market today It has been designed and manufactured with the ut...

Page 5: ...nks 52 4 4 1 General advice for interconnection of batteries 52 4 4 2 Parallel connection 52 4 4 3 Serial connection 53 4 4 4 mounting of ON OFF switch for bank operation 55 5 Charging via charging ch...

Page 6: ...overcharging cables and connectors or the battery itself In extreme cases even fire or injury may be the result Incorrect interconnection of lithium batteries induces much higher short circuit cur ren...

Page 7: ...t polarity when connecting equipment and chargers You will extend battery s service life if you do neither expose it directly to the sun nor to high ambient temperatures longer than necessary When sto...

Page 8: ...F to 131 F Typical storage time at 50 charge 1 year Max Connections 2S8P or 1S16P For larger battery banks refer to Torqeedo Max quick charge 100 A Charging time 1 2 hours Protection class IP 67 Water...

Page 9: ...ues are again within given range battery may be turned on again It will then be fully operable again 3 Equipment and operating elements 3 1 Scope of supply Full scope of supply of Power 26 104 battery...

Page 10: ...ng on For operation with the Cruise outboard motor To switch on the Power 26 104 shortly press ON OFF switch on remote throttle or tiller display Usage with other devices Turning on with on off switch...

Page 11: ...ated on top of the battery First connect positive then negative cable Secure Power 26 104 against slipping and tilting Only mount battery in a horizontal position grips directed upwards Do not place o...

Page 12: ...ly have the same state of charge Thus only use same type of batteries for interconnection same capacity age manufacturer and state of char ge and fully charge every battery separately in the charger b...

Page 13: ...rther pair of serially connected batteries 2S2P connection In the same way up to 8 pairs of serially connected batteries may be interconnected in parallel 4 4 4 Mounting of ON OFF switch for bank oper...

Page 14: ...lar regulators either distributed or explicitly approved by Torqeedo Do not connect generators directly with Power 26 104 Use a Torqeedo charger to charge Power 26 104 from generator In case you don...

Page 15: ...larly which should be more than 21 V in order to avoid total discharge Although the battery is protected against total discharge it will lose charge during storage When discharged to less than 14V bat...

Page 16: ...ctive rules you may dispose of your battery at a municipal collecting point for its proper disposal Part no Product Description 2206 00 Charger for Power 26 104 Charge current 10 A charges Torqeedo Po...

Page 17: ...ies were added that are not expressly permitted or recommended by Torqeedo previous services or repairs were not carried out by firms authorized by Torqeedo or non original parts were used unless the...

Page 18: ...do GmbH Service Center Friedrichshafener Stra e 4a 82205 Gilching Germany service torqeedo com T 49 8153 92 15 126 F 49 8153 92 15 329 North America Torqeedo Inc 171 Erick Street Unit A 1 Crystal Lake...

Reviews: