Error messages
8
Error messages
Drive system
Display
Cause
Troubleshooting
E02
Stator excess temperature (motor overheated)
After waiting for a short period (approx. 10 minutes), motor can be
operated slowly again.
Contact Torqeedo Service.
E05
Motor/propeller blocked
Put the main switch into the "OFF" position, and disconnect the batteries.
Release the blockage, and turn the propeller one further turn by hand.
Reconnect the batteries to the system.
E06
Voltage to motor is too low
Low state of charge of battery. It may be possible to restart the motor
slowly from the Stop position.
E07
Overcurrent to motor
Continue at reduced power.
Contact Torqeedo Service.
E08
Circuit board excess temperature
After waiting for a short period (approx. 10 minutes), motor can be
operated slowly again.
Contact Torqeedo Service.
E09
Water ingress to pylon
Contact Torqeedo Service.
E21
Incorrect calibration of accelerator lever
See accelerator lever manual.
E22
Magnetic sensor defective
See accelerator lever manual.
E23
Value range incorrect
See accelerator lever manual.
E30
Communication error with motor
Check the plug connections of the data cables. Check the cables. If
necessary, contact Torqeedo Service and inform them of the error code.
E32
Communication error for accelerator lever
Check the plug connections of the data cables.
Check the cables.
page 94 / 113