background image

 Three-phase  motors  should  be  protected  from 

overload by a safety switch for the motor. 

 We  recommend  using  a  connection  cable  type  H07 

RN-F type of an appropriate section according to the 
power  consumption  of  the  pump  motor  and  the 
number  of  drivers  required  for  the  number  of  motor 
phases plus the ground cable. 

 Before  connecting  the  motor,  check  the  type  of 

protection required. 

 For  three-phase  motors,  adjust  suitably  the  heat 

value  according  to  the  heat  protector  table.  For 
connection  “

”  set  the  protector  at  the  highest 

indicated  value.  For connection 

” set the protector 

at the lowest value. 

 Check  the  correct  arrangement  and  connection  of 

the earth wire in the equipment installation. 

 It  is  very  important  to  keep  to  the  installation  and 

electrical  connection  conditions.  Should  they  not  be 
heeded, the pump manufacturer does not accept any 
responsibility and considers the guarantee void.  

 The motors are subject to EEC standards with IP-55. 

 Special installation regulations may exist. 

 The  main  cable  can  only  be  connected  by  qualified 

and authorised personnel.  

 Incorrect mains connection could result in death. 

 
 

 

4.  START-UP INSTRUCTIONS  

 

QUESTIONS PRIOR TO START-UP 

 

 The  pumps  can  never  work  without  having  been 

previously  filled  with  water,  as  otherwise  it  may 
damage  the  mechanical  seal  causing  loss  of  water 
through it. 

 For  models  with  pre-filter  the  following  operations 

can be performed (Fig. 3): 

1.  Open the lid of the pre-filter (Fig. 5). 
2.  Fill  the  pump  with  water  through  the pre-filter 

until it dips into the suction tube. 

3.  If,  during  these  operations  the  basket  should 

have been taken out, do not forget to replace 
it  inside  the  pre-filter  so  as  to  prevent  large 
particles from entering the inside of the pump 
and thus blocking it 

4.  Close  the  pre-filter  without  forgetting  to  place 

the joint in their seat. (Fig. 5) 

 

 Die  Dreiphasenpumpen  müssen  mit  einem  Schutzschalter 

verschen sein um die überhitzung des Motors zu vermeiden.  

 Es  wird  empfohlen,  ein  Anschlusskabel  des  Modells  H07 

RN-F mit geeignetem Durchmesser für den Stromverbrauch 
des Pumpenmotors zu verwenden, das darüber hinaus eine 
angemessene Anzahl Adern für die Phasenzahl des Motors 
zuzüglich des Erdungskabels hat. 

 Vor 

Anschluss 

des 

Motors 

muss 

die 

benötigte 

Schutzvorrichtung geprüft werden.  

 Beim  Dreiphasen-Motor  stellen  Sie  das  Thermorelais 

entsprechend  den  Angaben  der  Wärmeschutzschalter-
Tabelle  ein.  Für  die  Verbindung  im  Dreieck  (

)  gilt  der 

höhere  der  genannten  Werte.  Für  ein  eine  „Y“  Verbindung 
gilt entsprechend der niedrigere Wert. 

 Beachten  Sie  beim  Einbau  der  Anlage  die  korrekte 

Verlegung und Verbindung der Erdungsleitung. 

 Bei  Missachtung  der  Anleitungen  zu  Einbau  und 

Elektoranschluss lehnt der Hersteller jede Verantwortung ab 
und die Garantie geht verloren.  

 Die  Motoren  unterliegen  den  EWG-Vorschriften  mit 

Schutzklasse IP-55. 

 Es können besondere Einbau-Richtlinien bestehen. 

 Das  Netzkabel  ist  nur  von  autorisiertem  Fachpersonal 

anzuschlie

en. 

 Falscher Netzanschluss kann lebensgefährlich sein! 

 

 

4. ANWEISUNGEN ZUR INBETRIEBNAHME 

 

VOR DER INBETRIEBNAHME 

 Die  Pumpen  dürfen  unter  keinen  Umständen  in  Betrieb 

genommen  werden,  wenn  sie  nicht  vorher  mit  Wasser 
gefüllt  worden  sind,  da  im  gegenteiligen  Fall  die 
Verschlussdichtung  beschädigt  werden  könnte,  was  zum 
entsprechenden Wasserleck führt.  

 Bei  den  Modellen  mit  Vorfilter  können  folgende  Schritte 

durchgeführt werden (Abb.3): 

1.  Abdeckung des Vorfilters öffnen (Abb.5). 
2.  Füllen  Sie  Wasser  durch  den  Vorfilter  in  die  Pumpe 

bis das Wasser in der Saugleitung erscheint. 

3.  Falls  Sie  während  dieser  Handgriffe  den  Korb  aus 

dem 

Inneren 

des 

Vorfilters 

entfernt 

haben, 

vergessen  Sie  nicht,  ihn  wieder  einzusetzen,  denn 
nur so können Sie vermeiden, dass gröbere Partikel 
ins  Pumpeninnere  dringen  und  möglicherweise  die 
Pumpe verstopfen.  

4.  Vorfilter  schließen,  ohne  dabei  zu  vergessen,  die 

Dichtung in ihrer Aufnahme zu platzieren. (Abb.5) 

CODE

VOLTAGE

INTENSITY RELAY REGULATION

Code

Voltzahl

Intensitätsrelais-Verordnung

SA033M

230  V

2,9 A

SA050M

230  V

3,8 A

SA075M

230  V

4,0 A

SA075T

230/400  V

2,4 / 1,6 A

SA100M

230  V

6,2 A

SA100T

230/400  V

4,7 / 2,7 A

SA125M

230  V

7,6 A

SA125T

230/400  V

6,1 / 3,5 A

Summary of Contents for SA033M

Page 1: ...SELF PRIMMING PUMPS FOR SWIMMING POOLS SELBSTANSAUGENDE PUMPEN FÜR SCHWIMMBECKEN INSTALLATION AND MAINTENANCE MANUAL TECHNICAL DATA HINWEISE FÜR EINBAU UND WARTUNG TECHNISCHE DATEN SA ENG GER ...

Page 2: ... In the case of defective operation or breakdown contact the nearest manufacturer s agent or the manufacturer s Technical Customer Service DEUTSCH Bitte beachten Sie Diese Anleitung enthält wichtige Sicherheitsbestimmungen deren Einhaltung bei der Installation und der Inbetriebnahme unbedingt erforderlich ist Lesen Sie bitte vor der Montage und der Nutzung alle Anweisungen 1 ALLGEMEINE SICHERHEITS...

Page 3: ... HINWEISE ZU INSTALLATIONS UND MONTAGEARBEITEN Beachten Sie beim Anschluss der Elektrokabel an den Motor die richtige Anordnung im Inneren des Anschlusskastens Lassen Sie keine Kabelreste im Inneren zurück und vergewissern Sie sich dass die Erdleitung korrekt angeschlossen ist Schliessen Sie den Motor entsprechend dem der Pumpe beiliegenden Schaltplan an Kontrollieren Sie dass die Elektrokabel ric...

Page 4: ...n Sie bis das Kreiselrad zum Stillstand gekommen ist Diese Liste hat nur Hinweis Charakter und schliesst zusätzliche spezifische Sicherheitsnormen nicht aus Kontrollieren Sie regelmässig Die korrekte Befestigung der mechanischen Teile und den Zustand der Schraubenhalterung des Gerätes Die richtige Position Befestigung und den Zustand der Speiseleiter und der Isolierung Die Temperatur der Maschine ...

Page 5: ...e Krafteinwirkungen auf Pumpe und Rohrleitung die nicht nur die Montage erschweren würden sondern auch zu einem Bruch der Teile führen könnten Abb 2 Installieren Sie die Saugleitung mit einer Neigung von 2 zur Pumpe Damit wird die Entstehung von Lufttaschen verhindert Abb 2 Für einen einwandfreien Betrieb der Pumpe muss diese zum Ansaugen gebracht werden bis das Wasser in der Saugleitung zu sehen ...

Page 6: ...nschlusskabel des Modells H07 RN F mit geeignetem Durchmesser für den Stromverbrauch des Pumpenmotors zu verwenden das darüber hinaus eine angemessene Anzahl Adern für die Phasenzahl des Motors zuzüglich des Erdungskabels hat Vor Anschluss des Motors muss die benötigte Schutzvorrichtung geprüft werden Beim Dreiphasen Motor stellen Sie das Thermorelais entsprechend den Angaben der Wärmeschutzschalt...

Page 7: ...e Netzspannung und kapazität mit den entsprechenden Angaben auf dem Typenschild der Pumpe übereinstimmen Überprüfen Sie beim Dreiphasen Motor den richtigen Drehsinn Den Drehsinn erkennen Sie am Ventilator im hinteren Teil des Motors den Sie durch das Sichtfenster im Deckel sehen können Abb 6 Die Achse der Pumpe muss sich frei drehen können INBETRIEBNAHME Öffnen Sie alle Ventile und lassen Sie den ...

Page 8: ...LEM URSACHE LÖSUNG DIE PUMPE FÜLLT SICH NICHT AUF Lufteintritt durch die Saugleitung Gewinde und Dichtungen der Saugleitung überprüfen Filterdeckel undicht Deckel des Vorfilters reinigen Zustand der Dichtungen überprüfen Drehsinn des Motors nicht korrekt III Zwei Versorgungsphasen umkehren Falsche Stromspannung Netzspannung muss dem Typenschild entsprechen DIE PUMPE LIEFERT WENIG FÖRDERLEISTUN G V...

Page 9: ...chrift Signature Carme Fusté Caixàs Managing Director of A 17 453 267 67 dBA 73 dBA SA033M SA050M SA075M SA100M SA125M SA075T SA100T SA125T 78 dBA INDICATIONS ON THE MAXIMUM AIR NOISE EMITTED Angaben zur maximal zulässigen luftschallemission CODE CODE CODE Code Code Code 1 HD006000 16 0 33 0 50 CV HD061000 32 0 33 0 50 CV 4 Unit MT101015 2 HD018000 16 0 75 1 1 5 CV HD061005 32 0 75 1 1 5 CV 4 Unit...

Reviews: